The Monitoring software is installed as a part of the Intellect software. Information about compatibility of the Intellect software versions and Monitoring is presented in the Obsolete. General information about product releases and versions compatibility section.
To install Monitoring software in the Additional workplace configuration, do the following:
- In the root directory of the distribution package, run the setup.exe executable file.
- To continue the installation process, click Next.
Installation of Additional workplace software is performed in the following sequence:
- From the installation kit, start the executable file setup.exe. A dialog box appears, informing of the beginning of installation. A prompt to start installation then appears. Click the Next button.
- The License Agreement window presents the terms of the end user license agreement. Select Read the terms of the license agreement carefully. Then set the radio button to I accept the terms of the License Agreement. Click the Next buttonagreement and click Next.
- On Set the next screen, select the Additional workplace installation type . Click and click Next.
- A dialog box to configure database connection will be displayed. Select the database server name and set up the connection parameters.
Click MS SQL Server and specify the authorization parameters for connection. For details, see Installation of INTELLECT™ software as a Server/Remote administrator workplace. To continue the installation process, click Next. In the Database field specify the name of
existingthe database or select it on the right part of the window in the list of databases, which are created in the server, and click <<. Then click Next.
Click NextInfo title Note By default, the name of the database is "MonitorSSTV" and its files will be stored in the SQL Server folder.
Specify the export catalog path. This catalog will contain video data received from Agent of Control.
Click Next.Specify IP-address and port for connection to Server of Control communication module videosrv.
Click Next.Info title Note. It is strongly recommended to change default Export catalog path and IP address on steps 6-7. Otherwise, after the installation is completed, it will be necessary to configure Additional workplace (see Configuring Additional workplace and Additional workplace of CSC).
- Click Install on the next dialog box to start the installation process.
The installation process is launched - As a result, the necessary components of the Monitoring software package will be copied to hard drive of your computer.
- When installation is complete, a wizard page appears with a message about successful installation. Click the Finish buttonAfter all software components are successfully copied on your hard drive, the message about the completion of the installation process will be displayed. Click Finish.
Installation of Additional workplace software is complete.