CARMEN-Auto module object settings panel contains the following interface elements:
The following table describes the elements of the CARMEN-Auto module object settings panel.
№ | Parameter name | Parameter setting method | Description | Data type | Default value | Value range |
---|---|---|---|---|---|---|
1 |
Minimum validity of LP type recognition field | Setting the value in the field | Set the minimal allowed validity of LP recognition | Integer non-negative number | 2 | 1-100 |
2 |
LP delimiter field | Setting the value in the field | Set delimiter in recognized license plates | – | - | – | |
3 | Recognition frame rate, fps field | Setting the value in the field | Set the number of frames per second processed by the recognizer. If you enter 0 or leave the field empty, the recognizer will process the maximum possible number of frames. | Integer non-negative number | - | >=0 |