Go to documentation repository
Page History
...
Most of the parameters are from the Record to archive command settings (see Record to archive). Other than that, there are following settings:
Select Alarm mode (1, always or only when there are no other active alarms for the camera).
Selecting a camera or group of cameras (2). An An implicit selection of a video camera is also allowed - − Camera that initiated command execution.
Note title Attention! If the start of the macro was triggered by the activation of input or output (see Configuring filters for event-driven macros) that is not connected to any camera, you need to select a specific camera here. If you select a group of cameras or a camera that triggered the command, the action will not start.
If you selected a group of cameras or an Axxon-domain at the previous step, you can select the Random (3) checkbox to initiate an alarm on a random camera from this group/domain.
- Select an archive to write to (4).
- In the Alarm flag position field, enter the number of seconds by which the alarm flag will be shifted back from the event time that started the macro (5).
...