Configuring the connection with ATM-Intellect Pro

To configure the connection with ATM-Intellect Pro, do the following:

  1. In the ATM IDfield specify identification number of the ATM. This value should match the "ID" value in the settings of ATM-Intellect Pro (1).
    Image Removed
    Image Removed Connection to drop-down list (1) select ATM-Intellect Pro.
    Image Added
  2. In the IP address field (2) specify the IP address of the computer on which Intellect and ATM-Intellect Pro are installed (2). If they are installed on the ATM's control computer, you can leave the default value unchanged (127.0.0.1).
  3. In the TCP portfield (3) specify the TCP port on which ATM-Intellect Pro expects  listens for connections from from ATM Event CaptureCapture utility. This value should match the TCP port (UPS-SCS) value in the settings of ATM-Intellect Pro (3Pro (see Setting the port used to listen for messages from the UPS and Smart Card Service ATMs).
  4. To save settings, click the Save button (4).

...

  1. .

Configuring the connection with Axxon Next

For the ATM Event Capture utility to work with Axxon Next, copy the Axxon Next license key — the license.key file into the utility installation directory. The ATMMonitoring module should be enabled in this key.

Note
titleAttention!
  • The ATMMonitoring position in the key should be equal to 1.
  • The key should contain a computer with the same name on which the ATM Event Capture utility is launched.
  • All MAC-codes of network interfaces, registered for this computer in the dongle, should match the real MAC-codes of the computer's network interfaces.

An Event Source object should be created and configured in Axxon Next (for details, see Configuring POS devices). The XML parser can be taken from the installation directory of the ATM Event Capture utility.

To configure the connection with Axxon Next, do the following:

  1. In the Connection to drop-down list (1) select POS.
    Image Added
  2. In the IP address field (2) specify the IP address of the computer on which Axxon Next is installed. If it is installed on the ATM's control computer, you can leave the default value unchanged (127.0.0.1).
  3. In the TCP portfield (3) specify the TCP port on which Axxon Next listens for connections from ATM Event Capture utility (see Connecting POS devices).
  4. To save settings, click the Save button.