When you are going to update the Intellect Axxon PSIM software, it is important to take the following peculiarities into account:

...

  1. Before updating the Intellect Axxon PSIM software, it is recommended to create a configuration backup copy and expand it after getting the new version installed, if necessary.

    Tip

    The full articles:Complete guides

    Creating the database backup copy

    Restoring database from backup copy


  2. You can update the Intellect Axxon PSIM software on top of the installed version without preliminary removing only in case if the second version number corresponds to both of the installed and new versions (i.e. you can update from 41.101.x to 41.101.y (x<y) or from 41.112.x to 41.112.y (x<y), but you cannot update from 41.10 1 to 41.112).

    Tip

    The full article: Updating INTELLECT™ Complete guide Updating Axxon PSIM™ software


  3. It is recommended to execute the Intellect Axxon PSIM software update with removing the old version in the following order:
  4. Execute the Intellect Axxon PSIM software removal using any of the ways described in the Removing INTELLECT™ Axxon PSIM™ software section.
  5. Remove the files left in the Intellect Axxon PSIM software installation directory (by default, C:\Program Files (x86)\IntellectAxxon PSIM\).

    Note
    titleImportant!
    To save the license, you need to copy the ‘intellectpsim.sec. activation key into the temporary storage before removing the files from this folder.


  6. Run the Intellect Axxon PSIM software new version installation.

    Tip

    The full article: Installing INTELLECT™ software

  7. When you are going to update from the 4.7.3 version to a newer one, you need to apply to the ITV manager for activation key regeneration since the Intellect software activation key operation principle has been changed starting with this version.
  8. MS SQL Server 2014 is being supplied as the part of the Intellect software distributives starting with the 4.10.0.1558 version, and for the older versions – MS SQL Server 2008. MS SQL Server is going to be updated to a newer version during the Intellect software update.

...

titleImportant!
  1. Complete guide Installing Axxon PSIM™ software