Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the Hardware tab in the System settings dialog box (1).
  2. Select the Camera object corresponding to the required camera in the objects tree (2). The settings panel for the selected object is displayed on the right of the Hardware tab.
  3. Go to the Basic settings tab on the settings panel of the Camera object (3).
    Image Modified
  4. In the Pre-alarm record field specify the required interval (sec) of pre-alarm events recording (4).
  5. Click the Apply button (5).

Information on pre-alarm recording options is given in the table.

Camera state

Recording initiator

Recording

Armed

Macro

Without pre-alarm recording

Armed

Manually

Without pre-alarm recording

Armed

Alarm

With pre- alarm recording

Armed

Program

With pre-alarm recording

Disarmed

Macro

Without pre-alarm recording

Disarmed

Manually

Without pre-alarm recording

Disarmed

Alarm

-

Disarmed

Program

With pre-alarm recording

In INTELLECT™ Axxon PSIM one can make pre-alarm recording if camera is disarmed.   One can do it with the help of DoReact("CAM","1","REC","rollback<1>") program; (see Programming Guide (JScript)  The Script object. Programming using the JScript language).