Go to documentation repository
The Telemetry controllerController object is designed used to register and configure in Axxon PSIM theserial ports (COM) ports used for connecting the PTZ units of the Intellect™ systemdevices.
The settings panel of the Telemetry controller Controller object is shown in the figure.
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Telemetry controllerController object.
№
| Parameter | Method for setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | Identification number* | Automatically | Displays the identification number of the Telemetry |
Controller object in the digital |
video surveillance system |
with the distributed architecture | Numbers, letters, periods, hyphen, dash and underscore | - | Depends on the number of the Telemetry |
Controller objects in the |
igital video surveillance system with the distributed architecture | ||
2 | Name* | Enter the value |
into the field |
Sets the name of the Telemetry |
Controller object in the digital |
video surveillance system |
with the distributed architecture | Latin, Cyrillic |
characters and service characters | Telemetry |
Controller No. | A line containing a sequence of any |
characters (letters, digits, service characters |
except > and < |
characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
3 | Disable |
Is identified by the check mark
Set the checkbox | Sets the state |
of the Telemetry |
Controller object (enabled or disabled) in the digital |
video surveillance system |
with the distributed architecture | Boolean type |
Not available
Clear | Set— |
the Telemetry |
Controller object is disabled and |
isn't used Clear—the Telemetry Controller object |
is enabled and is |
used | |
4 | Computer |
Select the value from the list |
Sets the Computer parent |
object of the digital |
system with the distributed architecture, to which the given Telemetry |
Controller object |
belongs | Name of the Computer objects registered in the system | Name of the Computer parent |
object |
Depends on the number of the Computer objects in the digital |
system with the distributed architecture | ||||||
The Settings group | ||||||
5 | Controller type* |
Select the value from the list |
Sets the data communication protocol with the PTZ |
device via the serial |
(COM) port. Data communication protocols are supplied by the PTZ |
devices manufacturers | Name of the PTZ |
devices integrated in the system |
Videotec | Corresponds to the list of the PTZ |
devices integrated in the system |
6 | Port |
Select the value from the list |
Sets the number of the computer COM port |
, used to |
connect the PTZ devices | List of the available COM ports |
COM1 | Depends on the number of COM ports |
on the |
Server or Remote |
Administrator’s workstation. If a non- |
null value is selected, then the local COM port |
has a higher priority than other devices when processing the PTZ device commands |
. |
Otherwise, the COM port priority is set |
by default |
7 |
Speed
Rate | Select the value |
from the list |
Sets the data communication rate |
via the COM port |
kB/ |
s |
9600 | From 300 to 256000 |
8 | Parity |
Select the value from the list |
Sets the parity check mode for the data |
transfer via the COM port |
List of parity check names and modes |
None | Even, Odd, None, Mark, Space |
9 | DTR |
Is identified by the check mark.
Set the checkbox | Sets |
the power supply to the PTZ |
device via the output of the |
DTR COM port |
Boolean type |
Set |
Set—the power will be supplied via the DTR port |
output |
Clear—the power will not be supplied via the DTR port |
output | |
10 | RTS |
Is identified by the check mark.
Set the checkbox | Sets |
the power supply to the PTZ |
device via the output of the RTS COM port |
Boolean type |
Set |
Set—the power will be supplied via the RTS port |
output |
Clear—the power will not be supplied via the RTS port |
output |