Go to documentation repository
The Control panel object is designed used to register and configure a specialized control panel used for to manage the PTZ control in the Intellect™ systemdevices in Axxon PSIM.
The settings panel of the Control panel object is shown in the figure.
Table The table describes the parameters of the settings corresponding to the elements of the settings panel of the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description |
Representation | Default value | Value range | |
1 | The Identification number* | Automatically | Displays the identification number of the Control panel object in the |
video surveillance system |
Sequence of numbers
with distributed architecture | Digits, letters, periods, hyphen, dash, and underscore | NA |
Depends on the number of the Control panel objects in the |
video surveillance system with distributed architecture | ||
2 | The Name* | Enter the value in the |
field |
Sets the name of the Control panel object in the |
video surveillance system |
with distributed architecture | Latin alphabet, Cyrillic and service characters | Control panel | A line containing a sequence of any |
characters (letters, digits, service characters |
except > and < |
characters), |
case- |
insensitive. Number of |
characters—from 1 to 60 |
3 | The Disable |
Is identified by the check mark
Set the checkbox | Disables the |
Control panel object |
in the |
video surveillance system |
with distributed architecture | Boolean type |
Not available
Clear | Set— |
the Control panel object |
is disabled and isn't used Clear— |
the Control panel object is enabled and is |
used |
4 |
Telemetry controller
The Telemetry Controller | Select the value |
from the list |
Sets the Telemetry Controller parent |
object of the |
system with distributed architecture to which the |
given Control panel object |
belongs |
Names of |
the Telemetry |
Controller objects registered in the system | Name of the Telemetry Controller parent |
object |
Depends on the number of |
telemetry controllers in the |
video surveillance system with distributed architecture | ||||||
The Settings |
group | ||||||
5 | The Port |
| Select the value |
from the list |
Sets the number of the computer serial (COM) port |
used to connect the control panel | List of available COM |
ports | COM1 | Depends on the number of COM ports |
on the |
server or Remote Administrator |
's workstation |
6 |
Speed
The Rate | Select the value |
from the list |
Sets the data communication |
speed via the serial (COM) port |
Kb/ |
s | 9600 | From 300 to 256000 |
7 | The Parity |
| Select the value |
from the list |
Sets the parity check mode for the data transmission over the serial (COM) port |
Names of the parity check modes |
None | Even, Odd, None, Mark, Space |
8 | The DTR checkbox |
Is identified by the check mark.
Set the checkbox | Enables power supply |
to the control panel via |
the output of the serial DTR (COM) port | Boolean type |
Set |
Set—the power |
is supplied via the DTR port |
output |
Clear—the power |
isn't supplied via the DTR port |
output | |
9 | The RTS |
Is identified by the check mark.
Set the checkbox | Enables power supply |
to the control panel via the output of the serial RTS (COM) port |
Boolean type |
Yes
Set | Set—the power is supplied via |
the RTS port |
output Clear—the power isn't supplied via the RTSport output |
10 | The Priority |
| Select the value |
from the list |
Sets the priority for controlling the PTZ |
devices via the |
control panel |
Names of priorities used to control the PTZ |
devices | Low |
|
|
|
|
|
|
Standard – the given PTZ can be controlled no sooner than when the PTZ with high priority has been controlled.
High – the PTZ with the given priority will be controlled first.
|
*Name of the element isn't *The name of the element is not displayed in the settings panel of the given object.