The settings panel of the SIP-terminal system object is shown in the pictures figures below.

Table The table describes the setting parameters of the SIP-terminal settings panel system object.

Parameter

Method for setting the parameter value

Description

Presented as

Representation

Default value

Range of values

Value range

1

The Identification number*
field

Automatically

Shows

Displays the identification number of the

 SIP-terminal system object

in the system.

Sequence of numbers

-

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the SIP-terminal objects in the system

.

2

The Name*
field

Enter the value in the field

Assigns a

Sets the name

to

of the SIP-terminal object in the system

.

Latin alphabet, Cyrillic

letters

, digits, and service characters

SIP-terminal

A line

representing

containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters),

not

case-

sensitive

insensitive.

Number of

symbols –

charactersfrom 1 to 60

.Shows the status (enabled or disabled) of the

3

The Disable
checkbox

Is set with a checkbox

Set the checkbox

Disables the 

SIP-terminal object in the system

.

Boolean type

-

Clear

Yes –

Setthe SIP-terminal object is disabled and

is not in use.No – the

isn't used

Clearthe SIP-terminal object is enabled and

is in use.

used

4

The Computer dropdown list

The Computer
drop-down list

Select the value from

Is selected in

the list

Assigns

Sets the Computer parent

Computer

object for the given SIP-terminal object

.

Name

Names of the Computer objects

registered in the system

.

Name of the Computer parent

Computer

object

Depends on the number of the Computer objects in the system

.

5The Terminal type switchSet the switch
to
in the required positionSets the SIP-terminal typeSupported SIP-terminal typesSIP server

SIP server

— the

—the SIP-terminal acts as a server, any SIP

-

clients can be connected to it

SIP client

— the

—the SIP-terminal acts as a client, it can be connected to any SIP

-

server

*Name of the element isn't displayed in the settings panel of the given object

The The Basic settings tab

Table The table describes the setting parameters of the the Basic settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Representation

Default value

Range of values

Value range

1The Network
drop-down list
Is selected in
Select the value from the list

Sets the IP address of the network adapter that

will be

is used to connect to the network

where

in which the SIP

-

clients are located

.

IP
-
addressDefault network adapterThe list of the available network adapters of the computer
2The SIP port fieldEnter the value in the field

Sets the port number which will receive the data from the clients via the SIP

-clients

protocol

Integer numbers5060From 0
-
to 65535
3The SIP transport
drop-down list
Is selected in
Select the value from the list

Sets the used transport

level

layer protocol

to be used.

Supported transport
level
layer protocolsUDP

TCP

UDP

4The RTP ports range, from and to fieldsEnter the value in the field

Sets the RTP ports range

Integer numbers

from

:

40000

to

:

64000

From 0
-
to 65535
5The Address fieldEnter the value in the field

For the SIP

-

client terminal type only.

Sets the IP address of the SIP

-

server

IP
-
address
-
NA1.0.0.0
-
255.255.255.255
The Port fieldEnter the value in the field

For the SIP

-

client terminal type only.

Sets the port for the SIP

-

server connection

Integer numbers
-
NAFrom 0
-
to 65535

The The Advanced settings tab

Table The table describes the setting parameters of the the Advanced settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Representation

Default value

Range of values

Value range

1The Subscriber
field
Enter the value in the fieldSets the SIP server special numberInteger numbers
-
NA>=0
2The Name
field
Enter the value in the fieldSets the name of the SIP server special numberLatin alphabet, Cyrillic
letters
, digits, and service characters
-
NAA line
representing
containing a sequence of any
symbols
characters

The Numbers settings tab

Table The table describes the setting parameters of the the Numbers settings tab.

Parameter

Method for setting the parameter value

Description

Presented as

Representation

Default value

Range of values

Value range

1The Subscriber
column 

field
Automatically
Lists
Displays the numbers of all devices and operators registered on the SIP
-
terminal, as well as special numbers
.
-
NA
-
NADepends on the number of devices and operators registered on the SIP terminal, as well as special numbers
-
2The Name
field
Automatically
Lists
Displays the names of the corresponding devices, operators, and special numbers
.---
Latin alphabet, Cyrillic, digits, and service charactersNAA line containing a sequence of any characters
3The Redirecting
field
Enter the value in the fieldSets the number or numbers to which the corresponding
subscriber
subscribers'
s
calls
should
must be forwarded
to.
Integer
Sequence of numbers
-
NANumbers of all devices and operators registered on the SIP
-
terminal, as well as special numbers. If you want to specify several numbers, use a semicolon as a separator, for example, 234;12;0983
4The Pending,
sec
s
field
Enter the value in the fieldSets the time period in seconds
,
during which
it is necessary to
you must wait for a response from the subscriber
.
Integer
Sequence of numbers
-
NA>0
5The One responder
checkbox
Set the checkboxEnables the reset of a group call
(redirected
forwarded to several numbers
) ending
after one of the recipients answersBoolean type
No
Clear

Set—the

Yes – a

group call is

ended at

reset for all recipients after the response of any operator or a device

.


No – the

Clear—the group call

is not ended

isn't reset after the answer of the first or subsequent operators and/or devices,

i.e.

that is, all recipients can join the call

.

6The Run macro
 drop

drop-down list
Is selected in
Select the value from the listSets the Macro object, which
should
must be run when calling
the subscribe.
to a subscriber

Names

Name

of the Macro objects

registered in the system

.

-
NADepends on the number of the Macro objects in the system
.
7The Calling number
multicast 
multicast (video)
field
Enter the value in the fieldSets the IP address for
broadcasting
transmitting the video stream from the calling device in the
multicast
 Multicast mode
.
IP
-
address
-
NA1.0.0.0
-
255.255.255.255
8The Calling number
multicast 
multicast (audio)
 field

field
Enter the value in the fieldSets the IP address for
broadcasting
transmitting the audio stream from the calling device in the
multicast
 Multicast mode
.
IP
-
address
-
NA1.0.0.0
-
255.255.255.255
9The Destination number
multicast 
multicast (video)
 field

field
Enter the value in the fieldSets the IP address for
broadcasting
transmitting the video stream from the destination device in the
multicast
 Multicast mode
.
IP
-
address
-
NA1.0.0.0
-
255.255.255.255
10The Destination number
multicast 
multicast (audio)
 field

field
Enter the value in the fieldSets the IP address for
broadcasting
transmitting the audio stream from the destination device in the
multicast mode.
 Multicast drop-down list modeIP
-
address
-
NA1.0.0.0
-
255.255.255.255