Create To create and configure the Camera object as follows, do the following:

  1. Select Create object -> Camera in In the context menu of the Video Capture Device objectcapture device object, select Create object Camera.
    Image Modified
  2. As a result, the basic settings toolbar panel of the object is displayed.
    Image Added

    Info
    titleNote

    Basic settings are specified set automatically. It is possible to change an If necessary, you can change the ID, object name, and parent object.

    Image Removed

  3. To Click the Apply button to create the object, click the Apply button.
  4. Select In the object tree, select the created Camera object in the object tree (1).
    Image Modified
  5. Configure the created object.:
    1. In the From the Channel number list (2) , select a physical video output of the card to which the camera is connected (see Features of video subsystem configuration section).

      Info
      titleNote

      Channel numbers within one Video capture card must not device object mustn't be repeated.

    2. In the Resolution list (3) , select the resolution with which the video signal is captured: Standard minimum accepted allowable value for the card, High – mean value —average value, and Full maximum accepted value with which a video signal is capturedallowable value.

      Note
      Info
      titleNote
      title

      Resolutions supported by video capture cards are given in Appendix 4. Technical specifications of video capture cards

      Info

      .

      While

      When configuring the

      video

      camera, which is connected

      through

      via the SC590N4 video capture card, in

      the Intellect software

      Axxon PSIM, you must set the frame resolution

      is

      equal to

      be set as

      the resolution set on the

      video

      camera. Otherwise,

      artefacts

      artifacts can appear on the video image.

      Info
      titleNote

      If If you are using the Stretch VRC-6404 HD video capture card is in use, then restart Intellect after changing resolution.  , make sure to restart Axxon PSIM whenever you change the resolution.

      Changing the Resolution doesn't guarantee that the resolution of the received video signal changes, as it depends, among other things, on the internal settings of the camera itself. If you need to specify certain streams strictly, it is better to configure multistreaming video.

    3. Click the Apply button to save the changessettings.

Configuring the Camera object is completedcomplete.

Repeat these actions the steps described in this section for all cameras connected to the card.

info
Info
titleNote

Number The number of the Camera objects that can be created under Video capture card object you can create on the basis of one Video capture device object is specified in Features of video subsystem configuration section.

titleNote

Detailed description of all settings of the Camera object is given in in Administrator's guideGuide.