The AIO input is configured on the settings panel of the Apollo AIO Input object, which is created on the basis of the Apollo AIO object.

The AIO input is configured as follows:

 Image Removed

  1. Select the input address from From the Number drop-down list, select the input address (1).
  2. Set the Configured checkbox if the input is in working state (2).
  3. Set the Tamper is normally opened checkbox if it's required to receive alarm events while breaking or opening the sensor housing (3).
  4. Set the Sensor is normally opened checkbox if it's required that input is to be in the normal state (not alarmalarmed) while opened when contacts are open (4).
  5. To require disarming of input set the corresponding checkbox Set the Request to disarm while entrance checkbox to disarm the input at entrance (5).
  6. In the Delay for entrance field, enter the value in seconds defining time for input disarming (6).
  7. In the Delay for exit field, enter the value in seconds defining time period during which the object can exit after the input arming (7).
  8. From the Mask by time zone drop-down list, select the time zone during which events won't be generated for the input (8).
  9. If necessary, assign the input with a term of an internal variable (9, see Associating AIO input with a term).

  10. Click the Apply button.

...

  1. Image Added button.