Configure the special operation mode on the Server of Of Control side as follows:
- Create and configure the Server of Of Control object on the Hardware tab (see Configuring Server of Control).
- Create and configure one or several External plates Plates DB objects on the Hardware tab (see Connecting and setting up of the external LP number database).
- Create and configure the Monitoring object object on the Interfaces tab (see Configuring the Monitoring PSIM interface object).
Image Modified - Create the ULPR section in the Windows registry if it is not created yet (see Registry keys reference guide for . For more details on how to operate the keyregistry, see Working with Windows OS registry for more details on how to operate registry).
- In the ULPR section of the Windows registry, create the ULPRspecialProcessing string parameter and set it its value to 1 (see Registry keys reference guide for . For more details on how to operate the keyregistry, see Working with Windows OS registry for more details on how to operate registry).
- Restart the computer to apply the changes.
As a result, the Info on vehicle license plates button becomes available in the Log panel and Details window of the Monitoring interface interface. The License plate search window opens when clicking you click this button (see Viewing recognized LPs).
Image Modified
Image Modified
Info |
---|
|
By default, the LP found in the database alarm is generated for the Entrance recognition point only. In order to generate alarm both on Entrance and Exit points, in the ULPR section of the Windows registry, create the AlarmMsgOne string parameter and set it its value to 0 (see Registry keys reference guide for guide. For more details on how to operate the keyregistry, see Working with Windows OS registry for more details on how to operate registry). |
Configuring the special operation mode on the Server of Of Control side is now completed.