Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To configure displaying the display of the Event viewer interface boxwindow, do the following:

  1. Go to the Main tab tab (1) on the settings panel of the Event viewer object (1).
    Image Added
  2. Set the
  3. X (horizontally indented from screen’s left border) and Y (vertically indented from screen’s upper border) coordinates of the upper left corner of the Event Viewer interface box (2).
  4. location of the Event viewer window:
    1. Enter the coordinates of the Event viewer window:
      1. X (2)horizontal indent from the left border of the screen;
      2. Y (4)vertical indent from the top border of the screen;
      3. W (3)width of the window;
      4. H (5)height of the window.
        Info
        titleNote

        Coordinates are set as a percentage of the corresponding screen dimensions horizontally and vertically,

  5. as followsSet the dimensions of the Event viewer interface box: window’s width «W» and window’s height «H» (3). Dimensions are set as a percentage of the corresponding screen dimensions horizontally and vertically, as follows
      1. respectively.

  6. Image Removed
    1. Click the Image Added button (6). This opens a window for setting the size and location of the Event viewer window using the mouse.
  7. From the Monitor drop-down list (7), select the number of the monitor for which coordinates are specifying (4)you set the coordinates.
  8. By default, the position of the Event viewer interface box window is fixed.  To To allow the Operator operator to move the Event viewer by left-clicking on it window with the left mouse button, set the the Allow moving checkbox (58).
  9. If it is necessary for the Event viewer box to window to be displayed on top of all windows, set the Over all windows checkbox (69).
  10. Set the background color of the Event viewer box window (710).
  11. Set the text color in the Event viewer box window (811).
  12. Set the color of alarm message rows messages in the the Event viewer interface box window (912). :

    1. For this, double-click

    upon
    1. the Color of alarm messages field

    . Standard Windows dialog box will open
    1. ;

    2. In the Color window that opens, select the required color

    and click OK
    1. ;

    2. Click the OK button.

      Info
      titleNote

      To apply the setting, the value of the Duration of blinking,

    sec
    1. s parameter (

    11
    1. 14)

    parameter value
    1. must be different from 0.

  13. Specify the color of information message rows info messages in the Event viewer interface box window (1013). :

    1. For this, double-click

    upon
    1. the Color of info messages field

    . Standard Color Windows dialog box will open
    1. ;

    2. In the Color window that opens, select the required color

    and click OK
    1. ;

    2. Click the OK button.

      Info
      titleNote

      To apply the setting, the value of the Duration of blinking,

    sec
    1. s parameter (

    11
    1. 14)

    parameter value
    1. must be different from 0.

    Enter
  14. In the Duration of blinking, s field (14), enter the duration of blinking for alarm messages in seconds
  15. in the Duration of blinking, sec field of the
  16. in the Event viewer interface
  17. box (11). The blink rate
  18. window.
    Info
    titleNote

    The blinking frequency is 2 seconds, and the

  19. blink
  20. blinking duration is 1 second. To ensure the blinking,

  21. it is recommended to set
  22. we recommend setting the parameter value to at least 2.

  23. Set the font of messages displayed in the Event viewer interface window:
    1. Click the Font:<current font> button (15);
    2. In the Font window that opens, set the font parameters;
    3. Click the OK button.
  24. By default, when
  25. the
  26. an alarm message has finished blinking, it is no longer highlighted by the alarm message color in the Event viewer
  27. box; it
  28. window. It becomes highlighted by the color specified in the filter (
  29. see 
  30. see Configuring event filters for displaying in the Event viewer).
  31. To continue highlighting the message by the alarm message color after the blinking stops, set
  32. the
  33. the Keep colored after blinking checkbox (
  34. 12
  35. 16).
  36. Set You can set the font of messages order of columns (17) that are displayed in the Event viewerinterface box. For this click the Font:<current font> button (13). Standard Font Windows dialog box will open, set the font and click OK window in two ways:
    1. Select the name of a column and move it with the mouse holding down the left button;
    2. Select the name of a column and move it with the left and right buttons.
      Info
      titleNote

      If you set the Hide Region and/or Hide Card checkboxes, the corresponding columns aren't displayed in the Event viewer window.

  37. Click the Apply button to save all the changes.

Parameters of displaying the Event viewer interface box window are now set.

Info
titleNote

The display of the Event viewer icon on the Windows taskbar is set by the ShowInTaskbar registry key (see Axxon PSIM base version).

...