Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The settings panel of the Video capture device system object is shown in the figure.

Image ModifiedTable

The table describes the setting parameters of the Video capture device system object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Video capture device system object

Sequence of numbers

-

NA

From 1 to 2147483647.

Depends on the number of

the

the Video capture device objects in the video surveillance system with distributed architecture

2

The Name*

Name 

field

Enter the value in the field

Sets the name of the Video capture device object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic

letters

, digits and service characters

Video capture device

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the status (enabled or disabled) of

Disables the Video capture device object in the video surveillance system with distributed architecture

Boolean type

-

Clear

Set—the Video capture device object is disabled and isn't

in use

used

Clear—the Video capture device object is enabled and

is in use

used

4

Computer 

The Computer
drop-down list 

Select a value from the list

Sets the Computer parent object for

this Video capture

the given Video capture device object

Name

Names of the Computer objects registered in the system

Name of the Computer parent object

Depends on the number of the Computer objects in the system

The Basic settings group

5

The Type
drop-down list 

Select a value from the list

Sets the type of the video capture board or the manufacturer of the IP device

Name

Names of the types of the video capture boards and the manufacturers of the IP devices

-


NA

  • Video capture boards (FS-3, FS-5, FS-6, FS-8, WS–4, WS-7/17,
etc.).
  • and so on);
  • Network video hubs (WaveHub);
  • Network devices (Axis, Panasonic, and others);
  • Virtual, Virtual bench
The IP device group
6The Model
drop-down list 
Select a value from the listSets the model of the IP deviceNames of the models of the IP devicesNAIntegrated models of the IP devices of the selected manufacturer
7The Firmware
drop-down list
Select a value from the listSets the firmware of the IP deviceNumbers of the integrated
firmware IP address
firmwares of the IP deviceNAIntegrated firmware of the selected IP device

8

PCI channel 

Select from the list

Sets number of the PCI channel of the video capture board ADC

List of connected channels for video capture

-

From 0 to 31, depending on the number of the PCI channels on the Server and the number of installed ADCs

9

Signal

Select from the list

Sets the format of the incoming video signal

List of video signal formats

PAL

PAL, NTSC

10

Resolution

Select from the list

Sets resolution of the video frames

List of video frame resolutions

Standard

Standard

High

Full

Specific values depend on the camera model

11

Speed

Set in the required position

Sets the frame rate of the video stream

Permissable changes of the total frame rate of the video signal transmission

Average

Depends on the capabilities of the IP-camera or video capture board. For boards with software compression:

Maxmaximum permissable total frame rate of the video signals

Averagehalf of the maximum permissable total frame rate of the video signals

Minone third of the maximum permissable total frame rate of the video signals

12

The IP address
field


Enter the value in the field

Sets the IP address of the network device

IP address

-

NA

A line presented as xxx.xxx.xxx.xxx

Contains

contains the values

:

from 0.0.0.0

to 255.255.255.255

Depends

and depends on the network settings of the IP devices registered in the system.

When

configuring getting

you get live video from the ECHD

Server

server, specify the following line in the field <ECHD

Server

server address>:<GUID cameras in the system>:<external account>

9

13

The Port

Port 

field

Enter the value in the field

Sets the connection port of the network IP device

Nonnegative

Non-negative integer

-

NA

From 0 to 65535.

Depends on the network settings of the IP device

14
10The RTSP
field
Enter the value in the fieldSets the RTSP connection port of the network IP device
Nonnegative
Non-negative integer
-
NA

From 0 to 65535.

Depends on the network settings of the IP device

15

11

The Name
field

Enter the value in the field

Sets the user name to connect to the network IP device

-

NA

-

NA

Depends on the network settings of the IP device

16


12

The Password
field

Enter the value in the field

Sets the password to connect to the network IP device

-

NA

-

NA

Depends on the network settings of the IP device

17

Activate watchdog 

Set the checkbox

Activates the Windows reset function, when Axxon PSIM main modules freeze

Boolean type

Clear

Set—the reset function of Windows OS is enabled

Clear—the reset function of Windows OS is disabled

18


13

The Use device settings
checkbox

Set the checkbox

Allows using the settings specified in the

Web-Server

web server or other software of the IP device

Boolean type

Clear.

Note. When

creating

you create the Video capture device object using the Camera discovery tool, the value of the checkbox depends on the settings configured in the

Wizard

discovery tool

Set—the settings of the IP device are used

Clear—the settings of Axxon PSIM are used

The Video capture card group

14

The PCI channel
drop-down list

Select a value from the list

Sets the number of the PCI channel of the ADC video capture board

List of connected channels for video capture

NA

From 0 to 31, depending on the number of the PCI channels on the server and on the number of the installed ADCs

15

The Signal
drop-down list

Select a value from the list

Sets the format of the incoming video signal

List of video signal formats

PAL

PAL, NTSC

16

The Resolution
drop-down list

Select a value from the list

Sets the resolution of the video frame

List of video frame resolutions

Standard

  • Standard;
  • High;
  • Full.

Specific values depend on the camera model

17

The Rate
slider

Set in the position

Sets the frame rate of the video stream

Permissible changes of the total frame rate of the video signal transmission

Average

Depends on the capabilities of the IP camera or video capture board. For boards with software compression:

  • Maxmaximum permissible total frame rate of the video signals;
  • Averagehalf of the maximum permissible total frame rate of the video signals;
  • Minone-third of the maximum permissible total frame rate of the video signals
Out of the group

18

The Activate watchdog
checkbox

Set the checkbox

Activates the Windows reset function when Axxon PSIM main modules freeze

Boolean type

Clear

Set—the reset function of the Windows OS is enabled

Clear—the reset function of the Windows OS is disabled


*Name of the element isn't displayed in the settings panel of the given object