The settings panel of the Microphone system object is shown in the figure.

Table The table describes the settings parameters of the Microphone system object.

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Microphone

object in the

system object 


Sequence of numbers

-

NA

From 1 to 32767.

Depends on the number of

the

the Microphone objects in the video surveillance system with distributed architecture

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Microphone object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic

characters

, digits and service characters

Microphone

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state of the Microphone object (enabled or disabled) in the system

Disables the Microphone object in the video surveillance system with distributed architecture

Boolean type

Clear

Setthe Microphone object is disabled and isn't used

Clearthe Microphone object is enabled and is used

4

The Audio card
drop-down list

Select the value from the list

Sets the Audio card parent object for the given Microphone object

Name


Names of the Audio card objects registered in the system

Name of the Audio card parent object


Depends on the number of the Audio card objects in the system

The General group

5

The Channel
drop-down list

Select the value from the list

Sets the number of

the channel for

the audio signal input channel according to the number of the RCA-F connector to which the microphone is connected


Right, left

chanel

channel

0

Depends on the type of

the

audio signal digitization card.

For AxxonSoft ADC

of the

audio signal digitization cards and audio cards such as SoundBlaster:

0Left channel;

1Right channel


6

The Line
drop-down list

Select the value from the list

Sets the source of audio signal

Type

Types of the audio signal source 

Microphone

Microphone—audio signal comes from the microphone

Phone—audio signal comes from the

telephone

phone line

7

The Gain
slider

Set the slider

into

in the

required

position

Sets the audio signal power gain

Sound power in decibels (dB)

24

From 0 to 45

8

The Volume level
indicator

Automatically

Displays the power volume of the incoming audio signal


Sound power in decibels (dB)

-

NA

From 0 to 45

The Driver parameters
group
table
9The Parameter
column
Automatically

Displays the available parameters of the IP device driver

-
NA
-
NADepends on the connected IP device
10The Value
column
Select the value from the list

Sets the values of the IP device parameters

-
NA
-
NADepends on the connected IP device and parameter
Not in
Out of the group
11The Audio delay field with buttonEnter the value
into
in the field using the up and down buttons

Sets the delay in milliseconds between the receiving of an audio signal from the audio input device and its output to the speaker or its recording to the archive

simultaneously

synchronously with the video signal. 

Note. This parameter is used if the video image comes delayed or advanced

,

and the sound is ahead or falls behind it

Sequence of
Integer numbers0-10000
10000

The AGC group

(set using the Olkha sound cards: Olkha-9P, Olkha-10LP, Olkha-12U, Olkha-14)

12

The Enable
checkbox

Set the checkbox

Enables the automatic adjustment of the audio signal gain

Boolean type

Clear

Set—automatic

Set—automatic adjustment of the audio signal gain is

enable

enabled

Clear—automatic

Clear—automatic adjustment of the audio signal gain is disabled

13

The Dynamic range
slider

Set the slider

into

in the

required

position

Set

Sets the level of audio signal power after the automatic adjustment

Sound power in decibels (dB)

0

From 0 to 45

14

The Time constant
slider

Set the slider

into

in the

required

position

Sets the time period

,

during which the audio signal is brought to the set power level

with

during automatic adjustment

Time in seconds (s)

3

From 0.1 to 6

The Audio trigger group

15

The Audio trigger level
slider

Set the slider

into

in the

required

position

Sets the level of the sound power

,

above which the recording of the audio signal starts automatically (registration of the alarm event)

starts automatically

Sound power in

standard

relative units

-45

-45—audio trigger is

off

disabled

From -44 to 0—audio trigger is

on

enabled


16

The Audio trigger delay
slider

Set the slider

into

in the

required

position

Sets the time period

,

during which the audio signal is post-recorded after the end of the alarm event


Time in seconds (s)

3

From 1 to 16

The Multicast group
17The IP
field
Enter the value
into
in the fieldSets the IP address from which the client
will receive
receives the audio data from the ONVIF
Server
server in the Multicast modeIP address224.0.0.
10
11224.0.0.
0 - 239
0—239.255.255.255
18The Port
field
Enter the value
into
in the fieldSets the port for transmitting the audio data in the Multicast modeSequence of numbersDepends on the number of cameras and streams in the system

Any valid unused port numbers.

The number of ports is determined by the system administrator

*Name of the element isn't displayed in the settings panel of the given object