Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The settings panel of the Failover service object is shown in the figure.

Image ModifiedTable

The table describes the setting parameters corresponding to the elements of the settings panel of the Failover service object.

 

Parameter

 

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Failover service object

Digits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Failover service object in the video surveillance system with distributed architecture

2

The Name*
field

Enter the value in the field

Sets the name of the Failover service object in the video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits, and service characters

Failover service

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of characters—from 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Failover service object in the video surveillance system with distributed architecture

Boolean typeClear

Setthe Failover service object is disabled and isn't used

Clearthe Failover service object is enabled and used

4

The Monitor PC
drop-down list

Select the value from the list

Sets the name of the

Server

server, the state of which

will be

is monitored by the object

Names of the Computer objects registered in the system

-

NA

Depends on the number of the Computer objects registered in the system

2

Speed ​​of object transfer to monitoring computer (rpm)

Enter the value into the field

Sets the speed of transferring objects in case the connection is lost. This setting is necessary so that the failover server sends messages at a certain speed and the receiving server has time to process them. The transfer speed should be set depending on the network speed, server bandwidth, etc.

Sequence of numbers

1000

From 0 and above

3

5

The Wait for reconnection (s) field

Enter the value

into

in the field

Sets the time period in seconds after which the configuration will be transferred to the backup

Server

server after the loss of connection with the monitored server

Sequence of numbers

-

NA

From 0 to 65535

4
6The Time left
__
50 days
field

Automatically

Displays the period of time in days remaining to restore the configuration from the backup

Server

server to the main

Server

server and restore the license.

The unit of measurement depends on the remaining time: if there is less than one day left before reconnection, the number of hours is displayed (for example, Time left 5 hours). If less than one hour—number of minutes (for example, Time left 5 minutes). If less than one minute—number of seconds (for example, Time left 0 seconds)

Days, hours, minutes, or seconds, depending on the amount of time remaining before reconnection

0

.00

From 0

.00 to 50.005

to 50 (days)

From 0 to 23 (hours)

From 0 to 59 (seconds and minutes)

7The Transfer if no ping
checkbox
Set the checkbox
Specifies if it is necessary
Sets the necessity to transfer the configuration without
the
a ping from the main monitored
Server
serverBoolean typeClear
Set—

Setthe configuration is transferred if there is no ping

Clear—ping

Clear—ping isn'

t

taken into account when

transferring

you transfer the configuration

6

Type

8

The Range
button

Click the button

Opens the window for the complex selection of the monitored objects

NA

NA

NA

The Objects table

9

The Type
drop-down list

Select the value from the list

Sets the object type in the configuration of the monitored

Server

server that

should

must be transferred to the backup

Server

server in case of connection loss

Types of objects registered on the basis of the main

Server

server

-

NA

Depends on the configuration created on the basis of the main

Server

server

7

10

The Number
drop-down list

Select the value from the list

Sets the identifier of the object of the selected type that

should

must be transferred to the backup

Server

server in case of connection loss

Identifiers of the objects of the selected type that are present in the configuration of the monitored

Server

server

-

NA

Depends on the number of the objects of the selected type in the configuration of main

Server

server

8

11

The Name field

Automatically

Sets the name of the object that

should

must be transferred to the backup

Server

server in case of connection loss

Names of the objects of the selected type that are present in the configuration of the monitored

Server

server

-

NA

Depends on the configuration created on the basis of the main

Server

9

Range

Click the button

Opens the dialog box for the complex selection of the monitored objects

-

-

-

server

*Name of the element isn't displayed in the settings panel of the given object