The Display object is used to register virtual displays in the system, which are used as a basis for interface components created in Axxon PSIM. The settings panel of the Display object is shown in the figure.

 

...

The table describes the setting parameters corresponding to the elements of the settings panel of the Display object.

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Display object in the

digital

video surveillance system with distributed architecture

Numbers

Digits, letters, periods, hyphen, dash, and underscore

-

NA

Depends on the number of the Display objects in the

digital

video surveillance system with distributed architecture

2

The Name*
field

Enter the value

into

in the field

Sets the name of the Display object in the

digital

video surveillance system with distributed architecture

Latin alphabet, Cyrillic, digits and service characters

Display

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Sets the state (enabled or disabled) of the Display

Displays the Display object in the

digital

video surveillance system with distributed architecture

Boolean type

Clear

Set—the Display object is disabled and isn't used

Clearthe Display object is enabled and used

The Computers group

4

The Select an element* checkbox

Set the checkbox

Contains a list of computers (

Server

server, Remote Administrator's workstation, Remote workstation) connected to the given

Server

server (Remote Administrator's workstation).

The checkboxes corresponding to the computers determine whether

or not

the computers

should

must display the Monitor objects created on the basis

on

of the given Display object

Boolean type

Clear

Set

the selected computer will display the Monitor

the Monitor object created on the basis of

the given

the Display

objectClear

 object is displayed in the selected computer

will not display the Monitor

Clear—the Monitor object created on the basis of

the given

the Display object isn't displayed in the selected computer

5

The Computer
field

Automatically

Sets the computer name in the local network

Computer name in the local network

Latin alphabet, Cyrillic, digits and service characters

Computer name in the local network

Depends on the number of objects in the local network.

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

6

The Name
field

Automatically

Sets the name to the computer in the

digital

video surveillance system with distributed architecture

Name of the Computer object registered in the system

Latin alphabet, Cyrillic, digits and service characters

Name of the Computer object registered in the system

Depends on the number of objects in the

digital

video surveillance system with distributed architecture.

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

The +Activate group
7The Number
drop-down list
Select the value from the listSets the number of
the Display
the display, the objects of which
will be
are displayed on the configured
Display
display at the same time with its objectsIdentifiers of
the
the Display
type
 type objects registered in the system
-
NADepends on the number of
the
objects registered in the system
8The Name
field
Automatically
Name
Sets the name of the
Display
display, the objects of which
will be
are displayed on the configured
Display
display.
Filled
It is filled out automatically after
selecting
you select the
Number
number
Name
Names of the Display
object
 objects registered in the system
-
NADepends on the number of
the
objects registered in the system

*Name of the element isn't displayed in the settings panel of the given object.