As soon as an alarm event is taken into processing, the alarm event recording is played back automatically one time, at 1X speed.
Playback is started starts:
- either from the beginning of an alarm event
...
- ;
- or from the moment corresponding to the position of the alarm event flag (only when the alarm event is initiated automatically
...
- -see Initiate alarm).
If the alarm event is initiated automatically, the visual element set for the detection tool, which initiated the alarm event, is displayed in the Surveillance window: either a detection area or virtual line that, when crossed, cause the detection tool to generate an event. The object that caused the detection tool to generate an alarm is outlined with a red border.
...