Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Section
Column
width50%
Panel
borderColor#CCCCCC
bgColor#FFFFFF
titleBGColor#F0F0F0
borderStylesolid
titleOn the page:

Table of Contents

Column



New integrations and supported devices

...

New AxACFA integrations

FINEACS.  Интегрировано устройство Integrated the FN-6535A . Реализована вычитка оборудования, получение состояний, управление дверьми.device. Implemented device reading, reception of statuses, and door control Image Added

New features and improvements

AxACFA modules

  • Protege:в документацию добавлена информация о формате строки поля Address, неправильное заполнение которого вызывало проблемы с вычиткой конфигурации Updated the documentation and included the information about the format of the Address field, as incorrect filling of the field caused problems with configuration reading  
  • RISCO Panel: в конфигурацию добавлены новые объекты RISCO Output и реализовано управление этими объектами. Added new RISCO Output objects to the configuration and implemented control of these objects Image Added

  • APACS:Corrected localization APACS: правки локализации 
  • Modbus Slave: стабилизирована повторная вычитка конфигурации, работа транспорта, изменения значений регистров хранения и работа функции отслеживания этих изменений Stabilized the repeated reading of the configuration, transport operation, changes to values of the holding registers, and the operation of the change-tracking function 

Integration modules

  • BioSmart:  исправлена динамическая запись уровней доступа Fixed the dynamic recording of access levels 
  • ZK Teco Image Removed
  • стабилизирована запись биометрических идентификаторов в устройства;
  • исправлены ошибки при отправке команд на контроллерImage Added
    • Stabilized the recording of biometric identifiers into devices.
    • Fixed the errors that occurred when sending commands to the controller.
  • Modbus Wrapper Image Added
    • Fixed the logic of stopping the poll when polled registers are deleted.
    • Fixed the problems with incorrectly determined error codes in the response from the Modbus device.
    • Fixed an infinite cycle of events when you tried to open a busy port.

    • Fixed the application of settings when you change the Modbus protocol and connection parameters.

Service modules

  • Access Manager
    • Added the ability to leave comments on access levels assigned to a user.
    • Stabilized the operation of the Access Manager module and its debugging tools.
    • Stabilized the re-accounting by protocol via the UpdateDB Utility. The re-accounting is started from the Worktime tab in the Access Manager interface window
    • добавлены комментарии к уровням доступа, назначенных пользователю;
    • стабилизирована работа самого модуля Бюро пропусков и его отладочных инструментов
    • .

Bug fixes

Fixed some errors in the ACS, FSA, PID modules. Improved the stability and performance of the system.

...