Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 5.3

...

Info
titleNote

For example, an operator can exit alarm mode to view the video archive related to the alarm

To configure alarm handling in the system, you must perform the following steps:

  1. Go to Settings Þ Options Þ Alarm Management Options  Alarm processing (1-2). 
  2. In the Alarm pending time group, enter the time in seconds during which it is necessary to accept the alarm for processing before it is assigned the Unclassified status (3).
  3. In the Operator's idle time field, enter the time in seconds during which an operator who accepted an alarm for processing and exited alarm mode without evaluating it must return to alarm mode (4).
  4. Click the Apply button.

Configuration of alarm handling is now complete.

Tip
iconfalse

Play corresponding video