Go to documentation repository
Page History
Section | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Configuring the parameters
...
To configure create the Handrail holding detectiondetector, do the following:
- Create Pose Detection (see
- the Human pose detector (see Configuring the Human pose detector).
- Below the Pose Detection, click
- Human pose detector, click Create… → Handrail holding detection
- detector.
The Handrail holding detection detector generates an event if there is a person in the specified area of the frame who doesn't hold on to any of the specified handrails.
If necessary, you can change the detection tool detector parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool detector is enabled by default. To disable the detection tooldetector, select the the No value value |
No | ||
Name | Handrail holding detectiondetector | Enter the detection tool detector name or leave the default name |
Type | Handrail holding detectiondetector | Name of the detection tool detector type (non-editable field) |
Basic settings | ||
Number of measurements in a row to trigger detection | 2 | Specify the minimum number of frames with the corresponding pose or behavior for the detection tool detector to generate an event. The The value must be in the range [1, 20]. The recommended (default) value is is 2. Increasing the value can help eliminate false events, but increases the risk of skips. Decreasing the value can help reduce skips, but increases the probability of false events |
To save the parameters of the detection tooldetector, click the Apply Apply button. To cancel the changes, click the Cancel Cancel button button.
Configuring the detection area
To configure the detection area of the the Handrail holding detectiondetector, do the following:
- Click in the preview window.
Note title Attention! - If lens distortion makes the handrail non-linear, use several lines to specify the handrail.
- The presence of a person in the staircase zone is determined by their lower limbs.
Using the Handrail line, specify one or several handrails in the frame.
- Using the anchor points of the Staircase zone, specify the zone ,
- in which a person must hold on to the handrail.
Info | ||
---|---|---|
| ||
|
Connfiguration of the Handrail holding detector is complete.
Overview
Content Tools