Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
title
Tip

Audio Hardware and audio data requirements for the operation of the Audio classification IV

Note

Attention!

The Microphone object must be enabled (see The Microphone object).

To configure the Audio classification IV, do the following:

  1. Submit to the technical support the MAC address of the Server server where the detector will be used.

    Note
    titleAttention!

    The detector will not work on the Server server with a different MAC address.

  2. Copy the license received from the technical support into the C:\Program Files\Common Files\AxxonSoft\DetectorPack\LicenseFile_AudioIV.txt file.
  3. Restart the Server server (see Shutting down a Server Stopping the server, Starting a Serverthe server).
  4. On the Detection Tools tab Detectors tab, below the required camera, click Create… Category: Production Safety Audio classification IV.

By default, the detector is enabled and set to recognize and detect all sounds specified in the settingsthe following types of sounds:

  • the sound of aggressive behavior,
  • the sound of a gunshot,
  • the sound of a smoke alarm,
  • the sound of a child crying,
  • the sound of breaking glass,
  • the sound of a siren,
  • the sound of a dog barking.

If necessary, you can change the detector parameters. The list of parameters is given in the table:

Note
titleAttention!

Recommendation for the sound detection threshold parameters: start with a value of 0.99 and gradually lower it if the detector misses target events, or increase it if there are too many false events.

  • A high value (close to 1): lower sensitivity, fewer false events, but a higher risk of missing an event.
  • A low value (close to 0.01): high sensitivity, better detection, but more false events.
ParameterValueDescription
Other
Enable YesBy default, the detector is enabled. To disable, select the No value
No
NameAudio classification IVEnter the detector name or leave the default name
Aggression detectionYes

By default, the aggression detection is enabled. To disable, select the No value

No
Aggression detection threshold0.99

Specify the sensitivity threshold value at which the sound is recognized as aggression. The value must be in the range [0.01, 1]

Baby cry detection YesBy default, the baby cry detection is enabled. To disable, select the No value
No
Baby cry detection threshold0.99Specify the sensitivity threshold value at which the sound is recognized as a baby cry. The value must be in the range [0.01, 1]
Dog bark detectionYesBy default, the dog bark detection is enabled. To disable, select the No value
No
Dog bark detection threshold0.99Specify the sensitivity threshold value at which the sound is recognized as a dog bark. The value must be in the range [0.01, 1]
Glass break detectionYesBy default, the glass break detection is enabled. To disable, select the No value
No
Glass break detection threshold0.99Specify the sensitivity threshold value at which the sound is recognized as glass breakbreaking. The value must be in the range [0.01, 1]
Gunshot detectionYesBy default, the gunshot detection is enabled. To disable, select the No value
No
Gunshot detection threshold0.99Specify the sensitivity threshold value at which the sound is recognized as a gunshot. The value must be in the range [0.01, 1]
Siren detectionYesBy default, the siren detection is enabled. To disable, select the No value
No
Siren detection threshold0.99Specify the sensitivity threshold value at which the sound is recognized as a siren. The value must be in the range [0.01, 1]
Smoke alarm detectionYesBy default, the smoke alarm detection is enabled. To disable, select the No value
No
Smoke alarm detection threshold0.99

Specify the sensitivity threshold value at which the sound is recognized as a smoke alarm. The value must be in the range [0.01, 1]

TypeAudio classification IVName of the detection tool detector type

To save the changes to the detection tool detector parameters, click the Apply button. To cancel the changes to the parameters, click the Cancel button.

...