Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The face of the settings panel for of the Monitor object is shown in the figures.

The Basic settings tab.

...

Image Modified

The List of cameras tab.

 Image Modified

The PTZ tab.

Image Modified

The Colors Interface tab.

Image Modified

The table Table describes the setting parameters of the Monitor interface object.

...


 

Parameter

Method

of

for setting the parameter value

Parameter description

Symbols used

Representation

Default value

Value range

1

The

Identification number

field

Automatically

Displays the identification number of the Monitor interface object in the system

.Sequence of numbers

Numbers, letters, periods, hyphen, dash and underscore

-

Depends on the number of the Monitor objects in the system

.

2

The

Name

field

Enter the value

in

into the field

Defines

Sets the name of the Monitor object in the system

.

Latin, Cyrillic and service

digits

characters

Monitor

A line containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters),

not

case-

sensitive

insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

3

The

Disable

checkbox

Set the checkbox

Defines the mode of the Monitor object

Sets the state (enabled or disabled)of the Monitor object in the system

.

Boolean type

-

Clear

Yes

Setthe Monitor object is disabled and

is not in use

isn't used

Clear

No

the Monitor object is enabled and

is in use

used

4

The

Display

drop-down list

Select

in

the value from the list

Sets the Display parent

Display

object

 for

for the given Monitor object

.

Names of the Display objects registered in the system

Name of the Display parent

Display

object

Depends on the number of the Display

object s

objects in the system

.

The Coordinates group

5

The

X

field

Enter the value

in

into the field

Set

Sets the X coordinate in the horizontal axis for the upper

-

left corner of the Monitor interface

box

window

% of the screen width

-

From 0 to M*100, where M is the number of the installed computer monitors

installed

6

The

Y

field

Enter the value

in

into the field

Set

Sets the Y coordinate in the vertical axis for the upper left corner of the Monitor interface

box

window

% of the screen height

-

From 0 to M*100, where M is the number of the installed computer monitors

installed

7

The

W

field

Enter the value

in

into the field

Set

Sets the width of the Monitor interface

box

window

% of the screen width

-

From 20 to 900 if

Control

control panel is enabled. Otherwise, from 0 to 900.

This

upper bound

restriction can be

removed

disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

.

8

The

H

field

Enter the value

in

into the field

Set

Sets the height of the Monitor object if the control panel is

not active

disabled

% of the screen width

-

From 0 to 900.

This restriction can be

removed

disabled using the UnlimitMonitorSize registry key (see Registry keys reference guide)

.

9

The

Monitor

drop-down list

Select the value from

Select in

the list

Sets the number of the physical monitor

number

, the coordinates for which are

assigned

set. The monitors are numbered in the order of their physical location from left to right, from top to bottom

, i

.

e. the

The 1st monitor is the one in the upper left corner regardless of which monitor is

assigned

set as main or what number the monitor has in OS.

Image Removed

Sequence of numbers

1

From 1 to 9

In the figure below, the monitor numbers in OS are given in gray while the numbers in Intellect are red.

Image Added

Attention! It is recommended to set the same resolution for all monitors in the system. Different resolution is only allowed if all monitors are aligned along any border (for example, upper border)

Sequence of numbers

1

From 1 to 16

10

Allow moving

10

The Allow moving checkbox

Set the checkbox

Allows

hand shifting of

moving the the Monitor interface

box

window manually, if the control panel is

active

enabled

Boolean type

-

Yes – hand shifting is allowed.

No – hand shifting is prohibited.

Clear

Set—the manual moving is allowed

ClearSet—the manual moving isn't allowed

11The X buttonClick the buttonOpens the window for specifying the position of the Monitor interface window---
The Quad splitter group
11
12horizontal
field
Enter the value
in
into the field

Sets the number of

video

the surveillance windows

in the horizontal direction to display then

that should be displayed horizontally on the Monitor. If value is not specified (the field is

empty

blank), then the default grid of

video

the surveillance windows depending on the selected layout is displayed

Natural
Sequence of numbers-From 1 to 64
12
13vertical
field
Enter the value
in
into the field

Sets the number of

video

the surveillance windows

in the vertical direction to display then

that should be displayed vertically on the Monitor. If value is not specified (the field is

empty

blank), then the default grid of

video

the surveillance windows depending on the selected layout is displayed

Natural
Sequence of numbers-From 1 to 64

The Basic settings tab

13

The Overlay drop-down list

14

Display

Select the value from

Select in

the list

Set

Sets the

Overlay

mode for processing the video signals from the video cameras by the graphics card

Names of

overlay

the display modes

Method2

DirectDraw (Recommended)

Method1 – video signals are processed as one stream

Method2 (Recommended) – video signals are processed independently from each other

Direct3D is used when it is necessary to display the video from the fisheye cameras or the signal decoded using Intel QuickSync technology

DirectDraw (Recommended) is used by default in all other cases

Programmed

None

video signals are not processed by

a video capture

the graphics card

14

15

The

Active camera

switch

Set

in

the

position

radio button

Set

Sets the display mode for an active camera

boxYes - The

window only

Boolean type

-

Clear

Setthe

 No - The

Active camera mode is enabled and

is in use

used

Clear—the

Active camera mode is disabled and

is not in use

15

The Alarms cameras switch

Set in the position

Set

isn't used

16

Alarm cameras

Set the radio button

Sets the display mode for alarm

cameras’ boxes

cameras windows

Boolean type

-

Clear

Setthe Alarm

Yes - The Alarms

cameras mode is enabled and

is in useNo - The

used

Clear—the Alarm

Alarms

cameras mode is disabled and

is not in use

isn't used

17

Max

16

The Max field

Enter the value

in

into the field

Specify

Sets the maximum number of the video cameras

, boxes of which are

windows that can be simultaneously displayed on the Monitor in the

Alarms

Alarm cameras and List modes

Sequence of numbers

-

From 1 to 64

Depends on

. If the number of alarm cameras is greater than the maximum number, the Monitor will display the number of cameras

registered

specified in the

system

17

The Min field

Enter the value in the box

Max field

An integer greater than zero (for example, 1, 2, 50)

-

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras

18

Min

Enter the value into the field

Sets

Specify

the minimum number of video cameras

, boxes of which are

windows that can be displayed on the Monitor in the

Alarms cameras even on no-alarm

Sequence of numbers

-

From 1 to 64

Depends on the number of cameras registered in the system.

0 – on no-alarm camera boxes are not displayed in the Monitor box.

18

The List switch

Set in the position

Set the display mode according to the selected layout.

Boolean type

Yes

Yes - The List mode is enabled and is in use

No - The List mode is disabled and is not in use

19

The Control panel checkbox

Set the checkbox

Alarm camers mode. If the number of the alarm cameras is less than the minimum number, the Monitor will display fewer cameras than specified in the Min field. At the same time, the Monitor fold will remain consistent with the Min field

An integer from zero and greater (for example, 1, 2, 50)

-

Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras.

0—when there are no alarms, the camera windows aren't displayed in the Monitor window

19

List

Set the radio button

Set the display mode of the surveillance windows according to the selected layout

Boolean type

Set

Set—the List mode is enabled and used

Clearthe List mode is disabled and isn't used

20

Control panel

Set the checkbox

Enables the display of the toolbar on

Activates the control panel for

the Monitor in the List mode

Boolean type

-

Clear

Setthecontrol panel

Yes - The Control panel mode

is enabled and

is in use

No - The Control panel mode is disabled and is not in use

20

The Telemetry control drop-down list

Select in the list

used

Clearthe control panel is disabled and isn't used

21

PTZ control

Select the value from the list

Sets the priority to control the PTZ devices using

Set the prioritiy for the Telemetry control using

the Monitor object

Names of the

Telemetry

PTZ devices control priorities

Low priority

Forbidden

—the option of the

Telemetry

PTZ control using the Monitor object is disabled

Low priority

low priority of control

Normal priority—medium priority of control

High priority

high priority of control

21

22

The

Slideshow

field

Enter the value

in

into the field

Set

Sets the period of the automatic slideshow of the camera

boxes

windows when the control panel is enabled

Period in seconds (s)

-

Whole number from 1 and bigger

22

Blank field

Blank field or 0the camera windows are scrolled every 3 seconds

An integer from 1 to 600the camera windows are scrolled at the specified interval

23

Keep camera ratio

The Keep camera ratio checkbox

Set the checkbox

Specifies

Sets the ratio of the width and height of the video image in the surveillance windows on the Video surveillance monitor

.

Boolean type

-

Clear

Yes –

Setthe ratio of the width and height of the video image corresponds to the ratio of the camera

.

No –

Clearvideo image fits the entire area of the Surveillance window, while the ratio may be affected

.

23

24

The

Show captions

checkbox

Set the checkbox

Shows the captions for the cameras of the Monitor interface

box

window.

In large distributed systems it is recommended to disable captions on those monitors where captions are not planned to be shown

in order to decrease the number of redundant events.Yes – The

Boolean type

Yes

Set

Setthe

Captions submenu is

available  No – The

available in the context menu of the Monitor interface

box

window

Clearthe

Captions submenu is

unavailable 

unavailable in the context menu of the Monitor interface

box24

window

 


25Smoothing
checkbox
Setting
Set the checkbox
Is

It is used when it is required to display video with greater resolution on which the ladder effect appears

while

when displaying in the small window.

Note. When this feature is enabled, the CPU load of the computer where the display is performed increases. It is recommended to use only to display video from analog cameras or low-resolution video

.

Boolean type
No
Clear
Yes

Setsmoothing is applied

.

No – smoothing is not

Clearsmoothing isn't applied

25

26

The

Audio player

drop-down list

Select

in

the value from the list

Sets the Audio player object used to playback the audio signals and export video recordings with audio from the Monitor interface

Names of the Audio player objects registered in the system

-

Depends on the number of the

audio

Audio players registered in the system

26
27Group of checkboxes used to
enable displaying
display the elements of the Surveillance
windows 
windows Set the checkboxesAllows enabling and disabling the display of various elements of the Surveillance window such as number, name, time, menu, camera frame and additional info on the camera, as well as the name of
video
Video surveillance monitorBoolean typeAll checkboxes are set
checked
except Additional info

Set

Yes

the corresponding element is displayed in the Surveillance windows of all cameras added to the Video surveillance monitor

.

No

Clearthe corresponding element

is not

isn't displayed in the Surveillance windows on the Video surveillance monitor

.

The List of cameras tab

27

28

The

Number

drop-down list

Select

in

the value from the list

Set

Sets the number of the video camera to display on the Monitor

Sequence of numbers

-

Depends on the number of the video cameras registered in the system

28

The

Camera

drop-down list

Select

in

the value from the list

Set

Sets the name of the video camera to display on the Monitor

Name of the cameras registered in the system

-

Depends on the number of the video cameras registered in the system

29

Video stream

drop-down list

Select the value from the list

 Set

Sets the number of the video stream displayed from the video camera

which is to be displayed when receiving video stream straight from camera

when connected directly. If connected via the Server, this setting doesn't affect anything

Numbers of the video streams

Streams numbers

Default

1, 2, 3, 4

video streams

.

numbers

Default

default video stream

.30

Connection

drop-down list

 

Select the value from the list

Set

Sets the way of receiving video image from the camera

Ways of receiving video

Through Server

Direct

-

the video stream is received

straight

directly from the camera

Through Server

-

the video stream is received from the Server, to which the camera is connected

to

31

The Fps drop-down list

fps

Select the value from

Select in

the list

Set the

fps

FPS for transmitting the video signal to the Client Monitor

of the Client.The

Sequence of numbers

-

1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30

32

Compression

drop-down list

Select

in

the value from the list

Set the compression level for transmitting the video signal to the Client Monitor

of the Client

.

 The

The given value leads to extra consumption of

Server’s

Server resources

.

Sequence of numbers

-

In the

range

order of

rising

increasing the compression level 0, 1, 2, 3, 4, 5

0

the video signal is not compressed

5

maximum compression of the video signal

33

Compressor

drop-down list

Select the value from the list

Specifies the procedure of

Sets the algorithm for the video stream compression which is

in use

used for the video signal recompression

for

when displaying on the Monitor.

The value is to be selected

If you set the compressor, you should also set the value in the Compression list

if the compressor is specified.

List of available

procedures

algorithms

-

MJPEG, Motion Wavelet 3.5,

Motion Wavelet 7.1

MPEG4

Gate

Select the value from

34

The Gate drop-down list

Select in

the list

Set

Sets the

Gate

Videogate object via which the live and archive video from the selected camera

is to

should be transmitted to the Monitor

Names of the

Gateway

Videogate objects registered in the system

-

Depends on the number of the

Gate

Videogate objects registered in the system

35

The

Backup archive

drop-down list

Select

in

the value from the list

Set

Sets the Backup archive object from which the video archive from the selected camera

of which is to The External

should be transmitted to the Monitor

Names of the Backup archive objects registered in the system

-

Depends on the number of the Backup archive objects registered in the system

36

Edge storage

Select

in

the value from the list

Set

Sets the

External

Edge storage object from which the video archive

from which is to

should be transmitted to the Monitor via the selected camera

Names of the

External

Edge storage objects registered in the system

-

Depends on the number of the

External

Edge storage objects registered in the system

37

The

Gateway for Backup archive

drop-down list

Select

in

the value from the list

Set

Sets the

Gate

Videogate object via which the video archive of the Backup archive object

is to be 

should be transmitted to the Monitor

Names of the

Gateway

Videogate objects registered in the system

-

Depends on the number of the

Gateway

Videogate objects registered in the system

38The Display type dropdown list
VMDA metadata storageSelect the value from
Select value in
the listSets
the type of conversion performed in the Surveillance window on the Video surveillance monitorSupported conversion typesPTZ

PTZ – virtual telemetry.

Panorama – panoramic view.
the VMDA metadata storage object used for the forensic search in the archive of the corresponding cameraNames of the VMDA metadata storage objects registered in the system-Depends on the number of the VMDA metadata storage objects registered in the system
Type of displaySelect the value from the listSets the type of conversion performed in the Surveillance window on the Video surveillance monitorSupported conversion typesPTZ

PTZvirtual telemetry

Panoramapanoramic view

Macro1Select the value from the listSets the first macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the system-Depends on the number of the Macro objects registered in the system
Macro2Select the value from the listSets the second macro to be displayed in the function menu of the camera in the Surveillance windowNames of the Macro objects registered in the system-Depends on the number of the Macro objects registered in the system
GuidAutomaticallyDisplays the unique identifier of the camera in the systemSequence of numbers, Latin and service characters-A line containing a sequence of any characters (letters, digits, service characters) enclosed in {curly brackets}

29

Range

Click the button

Access to complex selection and editing of cameras parameters to display on the Monitor

-

-

-

30

All

Click the button

Selects all cameras registered in the system to display on the Monitor

-

-

-

31

Automatic selection of streams for display

Set the checkbox

Enables the function of automatic selection of video stream for display on the Monitor. Affects cameras for which the On default video stream is selectedsee item 28

Boolean type

Clear

Setvideo stream for display is selected depending on the size of the video image on the Monitor and the required frame frequency

Clearvideo stream is selected depending on the Video stream and Connection settings and on the settings of the Server and video camera from which the stream is required

The PTZ tab

32

Mouse Behavior

-

The list of available actions with a mouse

-

-

-

33

Action

Select the value from the list

Sets the reaction performed when executing the corresponding action with a mouse

Reaction list of the PTZ device object

(Default)

Reaction list of the PTZ device object

34

Param.

Enter the value into the field

Sets the value of the reaction parameter if it’s required

Depends on the selected action

-

Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed, if the selected reaction allows speed specifying as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

35

Joystick Butt.

-

List of joystick buttons

-

-

-

36

Action

Select the value from the list

Sets the reaction which should be performed when clicking the joystick button

List of reaction

39

The Range button

Click the button

Select all cameras registered in the system to display on the Monitor

-

-

-

40

The All button

Click the button

Access to complex selection and editing of cameras’ parameters to display on the Monitor

-

-

-

41

Auto select of streams for displaying checkbox

Setting checkbox

Enables the function of auto select of video stream for displaying in the Monitor. Affects cameras for which the On default video stream is selected - see 25.

Boolean type

No

Yes - video stream for displaying is selected depending on the size of video image on the Monitor and required frame frequency

No -video stream is selected depending on the Video stream and Connection settings (25-26) and depending on settings of the Server and video camera from which the stream is required.

42

Mouse behavior

-

The list of available actions with a mouse

-

-

-

43

Action drop-down list

Select value from the list

Specify reaction performed while executing the corresponding action using a mouse

Reaction list

of the PTZ device object

(Default)

Reaction list

List of reaction of the PTZ device object

44


37

Parameter field

Param.

Enter the value

in

into the field

Specify

Sets the value of the reaction parameter if

it’s

it is required

Depends on the selected action

-

Depends on the selected

action. It is a preset number for

reaction. For the reactions connected with the presets,

for

it is a preset number. For other reactions, it is speed, if the selected reaction allows speed specifying as a parameter.

The

If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera

selected in

seleected on the Monitor

is in use if the parameter is not specified.

, is used

The Interface tab
38AlarmSelect the value from the list

Sets the frame color of the Surveillance window in the alarm state

RGB colorsRedRGB color palette
39ArmedSelect the value from the list

Sets the frame color of the Surveillance window when the camera is armed

RGB colorsYellowRGB color palette
40DisarmedSelect the value from the listSets the frame color of the Surveillance window when the camera is disarmedRGB colorsGreenRGB color palette
41No frame Select the value from the listSets the frame color of the Surveillance window when there is no frame in itRGB colorsBlackRGB color palette
42No signalSelect the value from the listSets the frame color of the Surveillance window when there is no signal from the cameraRGB colorsGreyRGB color palette
43Screen cacheSelect the value from the listSets the Surveillance window background color that is displayed when the video from the camera does not cover completely the Surveillance window, for example, when the camera proportions are maintainedRGB colorsPurpleRGB color palette
44Tracker frame color Select the value from the listSets the frame color to highlight the tracking objects on the video imageRGB colorsWhiteRGB color palette
45DefaultClick the button

Sets the default frame colors of the Surveillance window

---
46Hide capture framesSet the checkboxHides the frames displayed by the Face detection module when a person’s face is detected on the video imageBoolean typeClear

Setthe Face detection frames aren't displayed

Clearthe Face detection frames are displayed

47Over all windowsSet the checkboxEnables the display of the Video surveillance monitor on top of all windowsBoolean typeClear

Setthe Video surveillance monitor is displayed on top of all windows

Clearthe Video surveillance monitor is displayed in the default mode

48Camera switching dialogSet the checkboxEnables a special dialog for selecting a camera in the Surveillance windowBoolean typeClear

Seta special dialog is used for camera selection

Clearthe camera is selected in the function menu of the Surveillance window

45

Joystick buttons column

-

List of joystick buttons

-

-

-

46

Action drop-down list

Select value from the list

Specify reaction which is to be performed while clicking the joystick button

List of reaction of PTZ device object.

(Default)

List of reaction of PTZ device object

 

47

Parameter field

Enter the value in the field.

Specify the value of reaction parameter if it is required.

Depends on the selected action

-

Depends on the selected action. It is a preset number for reactions connected with presets, for other reactions it is speed if the selected reaction allow speed specifying as parameter. The speed value from the PTZ device object connected with Camera selected in the Monitor is in use if the parameter is not specified.

The Colors tab48Alarm dropdown listSelect value from the listSet the Viewing tile frame color if there is an alarm on the cameraRGB colorsRedRGB color palette49Armed dropdown listSelect value from the listSet the Viewing tile frame color when the camera is armedRGB colorsYellowRGB color palette50Disarmed dropdown listSelect value from the listSet the Viewing tile frame color when the camera is disarmedRGB colorsGreenRGB color palette51No frame dropdown listSelect value from the listSet the Viewing tile frame color when there is no frame from the camera in the Viewing tileRGB colorsBlackRGB color palette52No signal dropdown listSelect value from the listSet the Viewing tile frame color when there is no signal from the cameraRGB colorsGreyRGB color palette53Screen cache dropdown listSelect value from the listSet the Viewing tile background color that is displayed when the video from the camera does not overlay the Viewing tile, for instance, when the camera proportionsRGB colorsPurpleRGB color palette54Default buttonClick the buttonSet the default settings of the Viewing tile frame color---