Antivirus configuration (see Appendix 4. Using Axxon Next with anti-virus antivirus software):

  1. Add the following processes to the exclusion list:

    1. consul.exe
    2. nomad.exe
    3. apphost.exe
    4. postgres.exe
  2. Add the following folders to the exclusion list:
    1. C:\ProgramData\AxxonSoft\AxxonNext
    2. C:\Program Files\AxxonSoft\AxxonNext
    3. C:\Program Files\Common Files\AxxonSoft
    4. Postgres and metadata folders if their location is not default.
  3. Add the following ports to the exclusion list:
    1. 20109-20210
    2. If Failover Server and Client installation type is selected, then also add ports 4000, 4646-4648, 8300-8302, 8500, 8600.

...

Archive recording configuration (see Binding a camera Configuring recording to an archive):

  1. Link each camera to at least one archive.
  2. Configure recording to the archive (permanent or triggered by detection tools) for each camera.
  3. Make sure pre-recording is enabled (> 1 sec).

  4. Note that after you re-create the archive, it is necessary to re-create all recording rules in the detection tool settings or Programming settings.

...

  1. Create and configure an email notification (see The E-mail Objectnotifier object).
  2. Configure a cyclic macro command (once a day) to check if all cameras are recording (see Checking for archive video recordings, Cyclical macros).
  3. Configure event macros based on statistical data (CPU load, free disk space, see Triggering macros by statistical data).

...

  1. Do not use H.265 in camera settings since it causes the stream recompression on the Server side. It is recommended to use H.264 for such cameras.
  2. Change the HTTP port from 80 to a custom port (see Configuring the Web Server).

System check:

  1. Monitor the CPU load (<= 60%).
  2. Monitor the RAM load (<= 60%).
  3. Monitor the disk load:
    1. Active time is lower than 50%.
    2. Average response time is lower than 1 sec.

  4. Monitor free disk space: system drive has not less than 20 GB.
  5. Use the statistics panel in Web Client (see Viewing Camera and Archive Statistics).