The settings panel of the Camera object is shown in the figures.

The Basic settings tab:

...

Parameter

Method for setting the parameter value

Parameter description

Presented asRepresentation

Default value

Value range


1

Identification number

Automatically

Displays the identification number of the Camera  Camera system object in the system

Sequence of numbers

-

From 1 to FaceCamOffset. By default, FaceCamOffset = 50000.

The FaceCamOffset value is set using the same-name registry key (see Registry keys reference guide)

2

Name

Enter the value in the field

Sets the name of the Camera object in the system

Latin, Cyrillic and service characters

Camera

A line containing a sequence of any symbols characters (letters, digits, service characters except > and < symbols), case-insensitive.

Number of symbols charactersfrom 1 to 60

3

Region

Select the value from the list

Sets the Region structural element, to which this Camera object belongs

Name of the  the Region objects registered in the system

Region

Depends on the number of the Region objects registered in the system

4

Disable

Set the checkbox

Sets the status (enabled or disabled) of the Camera object in the system

Boolean type

Clear

Set the Set—the Camera object is disabled and isn't in use

Clear  the Clear—the Camera object is enabled and is in use

5

Video capture device

Select the value from the list

Sets the Video capture device parent object for this Camera object

Name of the Video capture device objects registered in the system

Name of the Video capture device parent object

Depends on the number of the Video capture device objects in the system

6

Video

Left-click

Displays video image with the configured settings.

When holding down the Shift key on the keyboard, opens the Web-Server page of the IP device in the default browser (doesn't work with Internet Explorer)

Video image

-

-

The Basic settings tab

7

Channel number 

Select the value from the list

Sets the number of the channel used to connect a video camera to the video capture board. Corresponds to the number of the BNC connector of the interface cable

Sequence of numbers

1

Depends on the type of the  video video capture board. Maximum 16 channels

8

Resolution

Select the value from the list

Sets the resolution of the video image frame

List of resolutions of the video image frame

Standard

Standard

High

Full

Specific values and their application depend on the camera model. If you want to use video streams with the exact resolution, it is better to use the Streams configuring setting (see parameter 43 and following)

9

Recording quality

Set the slider in the required position

Sets the quality of the recorded frame.

The value is inverse to the video signal compression level

-

Above average

Minmaximum compression level and the lowest video signal quality

Maxthe lowest compression level and the highest video signal quality

10

Color

Set the checkbox

Set the type of the video image received from the camera (color or black and white)

Boolean type

Set

Set the Set—the image from the video camera is in color

Clearthe image from the video camera is black and white

11

YUV 4:2:2

Set the checkbox

Sets the format of the color representation of the video signal

Boolean type

Clear

Set the Set—the video signal is represented in the YUV 4:2:2 format

Clearthe video signal is represented in the YUV 4:2:0 format

12

Color

Set the slider in the required position

Sets the color saturation of the color video image


From the maximum color saturation to a black and white video image

Average

Maxcorresponds to the maximum color saturation of the video image

Mincorresponds to the black and white video image

13

Brightness Contrast

Set the checkbox

Sets the mode for adjusting brightness and contrast of the video image

Types of modes for adjusting brightness and contrast of the video image

Automatic

Automatic (Position )Brightness and Contrast parameters are set automatically

Manual (Position )Brightness and Contrast parameters are set manually

Manual setting with automatic optimization (Position )Brightness and Contrast parameters are set manually, followed by automatic optimization

14

Brightness

Set the slider in the required position

Sets the brightness of the video image

From the maximum brightness (white video image) to minimum brightness (black video image)

Average

Maxcorresponds to the maximum brightness of the video image

Mincorresponds to the minimum brightness of the video image

15

Contrast

Set the slider in the required position

Set the contrast of the video image

-

Average

Maxcorresponds to the maximum contrast of the video image

Mincorresponds to the minimum contrast of the video image

16

Size

Set the slider in the required position

Sets the minimum size of an object at which the main motion detection tool triggers


% of the screen height

Average

Min0% of the video surveillance window size

Max100% of the video surveillance window size

17

Contrast

Set the slider in the required position

Set the minimum contrast of an object at which the motion detection tool triggers


-

Less than average

Maxcorrespond to maximum contrast of the object

Mincorresponds to the minimum contrast of the object

18

Record alarms

Set the checkbox

Starts automatic video signal recording on the alarms from the camera

Boolean type

Set

Set automatic Set—automatic video signal recording on the alarm from the camera is enabled

Clearautomatic video signal recording on the alarm from the camera is disabled 

19NumberSelect the value from the listSets the number of the microphone, the audio from which should be recorded simultaneously with the video signal from the cameraNumbers of the Microphone objects registered in the system-Depends on the number of the Microphone objects registered in the system
20MicrophoneSelect the value from the listSets the name of microphone, the audio from which should be recorded simultaneously with video signal from the cameraNames of the Microphone objects registered in the system-Depends on the number of the Microphone objects registered in the system

21

Pre-alarm record

Enter the value in the field

Set the time period that precedes the alarm record, during which the prehistory of the event is recorded

Time in seconds (s)

-

Recommended timefrom 0 to 20

22

Post-alarm record

Enter the value in the field

Sets the time period, during which the video is recorded after an alarm was registered

Time in seconds (s)

-

Recommended timefrom 0 to 20

23

"Hot record" time

Enter the value in the field

Sets the time period from the moment the alarm is registered or recording begins, during which the video is recorded at the frame rate set in the "Hot record" rate field

Time in seconds (s)

-

Recommended timefrom 0 to 30

24

"Hot record" rate

Enter the value in the field/select from the list

Sets the frame rate of the alarm hot recording

FPS

-


Depends on the capabilities of the camera

Recommended valuefrom 0 to 20

25

Recording frame rate

Enter the value in the field/select from the list

Sets the frame rate of the video signal recording

FPS

-

Depends on the capabilities of the camera

Recommended valuefrom 1 to 25 for PALFrom ; from 1 to 30 for NTSC

The Advanced settings tab

26

DecompressorSelect the value from the list

Sets the technology using which the compressed video stream will be decompressed when displaying the video signal on the monitor

Note. By default the parameter is not available for editing. To change the value of this parameter set the 1 value for the EnableCodecSettings registry key (see Registry keys reference guide)

List of available decompressorsNo

BOSCH

FfmpegAllInOneDecoder

H263IppDecoder

H264InterlacedIppDecoder

H264IppDecoder

MJPEGIpp

Motion Wavelet 3.5

Motion Wavelet 7.1

MPEG2IppDecoder

MPEG4IppDecoder

MxPEG Mobotix

RGB24toYUV420

StreamLabs

VWV

WMVIppDecoder

27

Compressor 

Select the value from the list

Sets the algorithm of the video stream compression 

Note. By default the parameter is not available for editing. To change the value of this parameter set the 1 value for the EnableCodecSettings registry key (see Registry keys reference guide)

List of available algorithms

No

Depends on the camera model

28

Estimate motion

Enter the value in the field

Sets the threshold of the camera sensivity to motion depending on the change of the object brightness. The delta frame of the video signal is formed according to this criterion

Sequence of numbers

7

From 2 to 255

29

Key frames interval

Enter the value in the field

Sets the rate of the key frames

Sequence of numbers

8

Depends on the capabilities of the camera

The Store no less than group

30

Store no less than

Enter the value in the field

Set the time period for keeping the video archive from the camera and audio archive (in case of synchro recording) on the Server. The parameter allows storing the large archive for the selected camera using the archive of other cameras

Note. It is recommended to set the Store no less than parameter for no more than 30% of cameras, as this setting is only advisory. If there isn't enough space for the archive recording, the setting will be ignored and the recording won't stop anyway.

If more than 10 cameras are created in the system, then when setting this parameter for more than 30% of cameras in the system, after you click the Apply button, a corresponding warning message will appear. It can be disabled using the NotifyAbout_arch_days registry key (see Registry keys reference guide)

Day or hour depending on the value selected in the drop-down list

-

More than 1

31Store no less thanSelect the value from the listSets the units for time period specified in the Store no less than fieldList of available time unitsDays

Days

Hours

The Store no more than group
32Store no more thanEnter the value in the field

Sets the time period for storing the camera archive. When it is expired, the camear archive should be deleted


Note. The archive can be deleted before the specified time if it is required for loop recording
Day or hour depending on the value selected in the drop-down list-More than 1
33Store no more thanSelect the value from the listSets the units for time period specified in the Store no more than fieldList of available time unitsDays

Days

Hours

Not in groups
34Additional infoEnter the value in the fieldSets the information displayed on the video surveillance monitor above the camera name. This information is added to the export file and when the frame is printed, as well as to the event log  logLine not longer than 100 charactersBlank lineLatin and Cyrillic letters, numbers

35

Type

Select the value from the list

Sets the type of the camera. The setting affects the type of the icons used to represent the camera on the map

List of available camera types

-

Fisheye

PTZ

Standard

36

Processing priority

Set the slider in the required position

Sets the priority of the video signals processing by ADC

Order of video signals processing

Normal

Normalnormal video signals processing order

1/31/3 processing order

1/21/2 processing order

37

Recording priority

Set the slider in the required position

Set the priority of video signals processing by ADC in the recording mode

Order of video signals processing in the recording mode

Normal

Normalnormal video record order

1/3  1/3 processing order

1/21/2 processing order

Real timeall ADC resourses are used for video signals recording

38

Rotation mode

Set the checkbox

Enables the rotation the the video image displayed on the Video surveillance monitor 

Boolean type

Clear

Set —rotation Set—rotation is enabled

Clearrotation is disabled

39

Rotate on

Select the value from the list

Specifies the angle of video image rotation when the rotation mode is enabled

Sequence of numbers

0

0, 90, 180, 270

40Lens type

Select the value from the list

Sets the type of lens to useSupported lens typesNo

No— select —select if there are neither fisheye nor panomorph lens on the camera

Standard fisheye lens— select —select if there is a fisheye lens on the camera

Autocalibration— select —select if there is a fisheye lens on the camera and the video conversion parameters should be automatically determined to eliminate artifacts

A0*V, A1UST, A8TRT, B0QQV, B4QQV, B5SST, B6SSTtypes of panomorph lenses

41Camera position

Select the value from the list

Sets the position of the cameraSupported camera position optionsCeiling

Ceiling

Wall

Floor

42Visible partEnter the value into the field

Determines what part of the frame will be visible on the Video surveillance monitor after the conversion

Percentage

75% for the Ceiling position

66% for the Wall position

Note. The default value may not be displayed in the field

0-100
The Streams settings tab

43

Streams configuring checkbox

Checking Set the boxcheckbox

Enables the video signal multistream feature

Boolean

NoClear

TrueSet—video signal multistreaming is enabled; different streams can be used for analytics, archiving, and display.

FalseClear—video signal multistreaming is disabled; a single stream is used for analytics, archiving, and display.

44

# field

AutomaticallyShows Displays the number of the stream numberInteger-1-10
45Enabled checkbox*Checking Set the boxcheckboxSets the enabled used camera streamsBooleanNoClear

Yes – the Set—the stream is in useNo

– the Clear—the stream is not in use

46

Default checkboxDefault

Checking Set the boxcheckbox

Assigns Sets the video stream to be displayed both as that will be used in the following cases:

  1. to display video locally and on the remote clients

List of available streams

No

  1. ;
  2. to send the video stream to the remote clients and to the Videogate that will record this video stream;
  3. in cases when video request doesn't specify the stream

List of available streams

Clear

Set—the stream is used by default

Clear—the stream isn't used

Yes – the stream is in use by default

No – the stream is not in use by default


47

Video analytics checkbox

Checking Set the boxcheckbox

Assigns Sets the video stream used  used for video analytics (including main motion detection tool). This stream is used by all Intellect detection tools (except embedded video camera detection tools) – including tracking detection tools, motion detection tool, face detection tool, facial recognition tools and detection tools that are the part of Detector Pack. .

This stream will be used by the base motion detection tool, zone detection tools, tracking detection tool, face detection tool (if an external recognizer isn't used).

The Default stream is used for the LPR server, face detection tool (if an external recognizer is used), and the detection tools that are part of the Detector Pack.

The Archive/Archive (alarms) stream is used for the long-term archive

List of available streams

NoClear

Yes – the Set—the stream is in use used for video analyticsNo – the stream is not in

Clear—the stream isn't use for video analytics

48

Archive checkbox

Checking Set the boxcheckbox

Sets the video stream that is recorded to the archive not upon alarm – the continuous recording is performed., but continuously

List of available streams

NoClear

Yes – the Set—the stream is in use used for archive recordingNo – the stream is not in use

Clear—the stream isn't used for archive recording

49Archive (alarms) checkbox
Checking Set the boxcheckbox Sets the video stream recorded to the archive upon alarm.List of available streamsNoClear

Yes – the Set—the stream is in use used for archive recording by upon alarmNo – the stream is not in use

Clear—the stream isn't used for archive recording by upon alarm

The Main stream tab
50IP fieldEnter the value in the fieldSets the IP address from which the client will receive the video data from the ONVIF Server in the Multicast mode.IP address224.0.0.10224.0.0.0 - 239.255.255.255
51Port fieldEnter the value in the fieldSets the port for transmitting the video data in the Multicast mode.NumbersSequence of numbersDepends on the number of video cameras and streams in the system

Any valid non-busy unused port numbers.

The number of ports is determined by the system administrator.

The Video stream tab

52

Purpose field

-

Displays a description of how Provides information about the use of the video stream is used

String

Depends on the video stream 's designated purpose

Most Latin and Russian Cyrillic characters, numbers

53

Resolution dropdown list**

Selected Select the value from a the list

Assigns Sets the video stream 's resolution

List of ­supported­ video­ resolutionssupported resolutions of the video image frame

Standard

Standard

High

Full

Particular values depend on the camera model.

54

Speed spinbox**

Typed into a Enter the value in the field

Assigns Sets the frame rate of the video stream

Frame rate (fps)in FPS

25

Depends on the capabilities of the camera

55

Codec dropdown list**

Selected Select the value from a the list

Assigns Sets the technology to be used to encode and decode the video stream

List of supported codecs

Depends on the camera model

Depends on the camera model.

56

Key frame rate spinbox**

Typed into a Enter the value in the field

Assigns Sets the key frames rate.

Set Sequence of natural­ numbers

8

Depends on the capabilities of the camera

57

Video quality slider**

Moving it to a Set the slider in the required position

Assigns Sets the frame quality

-

Maximum

Min maximum compression and minimum video signal quality

Max minimum compression and maximum video signal quality

58Lock disabling streams not in use checkboxSetting a Set the checkbox

This checkbox is to should be set checked if the purpose is not specified for the configured stream but it is is in use used for recording on command a macro or a script.

BooleanNoClear

Yes – if Set—if the stream value is not selected, then purpose isn't specified, the stream is in the sleep mode and it cannot be in use used for recording on command a macro or a script.

No

Clear—if the stream purpose

is not selected, then

isn't specified, it can be

in use

used for recording on

command

a macro or a script

.

59IP fieldEnter the value in the fieldSets the IP address from which the client will receive the video data from the ONVIF Server in the Multicast mode.IP address224.0.0.10224.0.0.0 - 239.255.255.255
60Port fieldEnter the value in the fieldSets the port for transmitting the video data in the Multicast mode.NumbersSequence of numbersDepends on the number of cameras and streams in the system

Any valid unused port numbers.

The number of ports is determined by the system administrator.

*Name  Name of the interface element is not shown isn't displayed on the setting settings panel.