- Low-level protocol. The system developer presented events, reactions and equipment connection commands as the byte set, so the equipment can be directly connected to Intellect.
SDK – —Software Development Kit. The system developer presented SDK, so the equipment can be directly connected to Intellect.
- Communication server (Program-driver). The system developer presented own driver (program layer between AxxonSoft software and hardware in which events, reactions, configuration commands and state request are built in) in order to connect the equipment. Install the third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. COM-server and OPC-server are examples of such programs.
- API - —Application Programming Interface. The system developer presented an API for working with equipment through the built-in Web server, so the equipment can be directly connected to Intellect.
SOFT-SOFT. The system developer presented an API for using its commands in Intellect and vice versa in order to connect the equipment. Install the full version of third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. to access the event log.
Info title Note Hardware connection interface is not specified for soft-soft integrations because ACFA Intellect connects with 3d party software and not with the devices directly. Please contact the 3d party software vendor in order to get information about the hardware connection interface.
Universal protocol integration: OPC, SNMP, BACnet, and Modbus. OPC and BACnet are industry standards. The system developer makes OPS-server and BACnet-server implementation for its devices and sends data over OPC or BACnet protocols. Intellect is the client for such servers and it gets data (events, reactions, configuration commands, etc.). SNMP is a network protocol used to monitor some devices. The list of some hardware connected to Intellect over universal protocols is specified in the Systems connected by universal protocols section.
- Drivers Pack. An equipment was integrated using one of the above methods via Axxon Drivers Pack. When using this integration method, it is necessary to install not only ACFA Intellect (version 6.4 and higher), but also the Drivers Pack (version 3.49 and higher).
...
Info | ||
---|---|---|
| ||
...
Common name | Integrated hardware (name of devices) | Functionality | Name in price list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA Intellect version | ||||||||
Noder | EWE4 controller EE12 controller EW2 controller EWE2 controller Reader MD-R / W Reader with MDK-R keypad Expansion board for elevator control IO16RS Converter RS -> Wiegand | Monitoring, configuration, control | INTELLECT Access Control Service (Noder EW2/EWE2), per controller INTELLECT Access Control Service (Noder for KONE DCS), per elevator group INTELLECT Access Control Service (Noder EWE4), per controller INTELLECT Access Control Service (Noder EE12), per controller | low-level protocol | Ethernet | 6.9.4500 | |||||||||
Castle | Pro, Pro4, RS, ES, EP, EP2, EP4 | Monitoring, configuration, control | Intellect Access Control Service (Castle), per IP | Castle Creations | communication server | USB-RS485, Ethernet | - | ||||||||
Honeywell N-1000 (past Northern Computers) | N-1000 | Monitoring, control | INTELLECT Access Control Service (Honeywell N-1000-IV), per COMport | Honeywell Systems Group Video and Access Control Solutions www.security.honeywell.com | low-level protocol | RS-232 | - | ||||||||
Sigur | EAll Sigur access controllers, including E100, E300H, R500D4/E500D4, R500/E500, E500U/R500U, R900I/E900I, E900U/R900U, E2, E4, etc. | Monitoring, configuration, control | INTELLECT Access Control Service (Sphinx), per access controller | «PromAvtomatika Service» | SOFT-SOFT | - | - | Paxton | Net2 nano Net2 plus Net2 classic Net2 I/O Board | Monitoring, configuration, control | Intellect Access Control Service (PAXTON), per Controller | Paxton | SOFT-SOFT | - | - |
SALTO | CU50ENSVN, GateWay, Encoder | Monitoring, configuration, control | INTELLECT SALTO integration module | Salto www.saltosystems.com | SOFT-SOFT | - | - | ||||||||
ZK Teco | C3-100, C3-200, C3-400 | Monitoring, configuration, control | INTELLECT Access Control Service (ZKAccess), per door | ZKTeco | SDK | Ethernet, RS485 | 6.2 | ||||||||
Schindler elevator controller | Monitoring, configuration | INTELLECT Access Control Service (Schindler Port), per controller | Schindler Management Ltd | SDK | Ethernet | 6.8 | |||||||||
Unicard U700 | U700 controller | Monitoring, configuration, control | INTELLECT Access Control Service (UNICARD), per access control point | Unicard SA | low-level protocol | Ethernet | 6.2 | ||||||||
Axis | A1001 | Monitoring, control | INTELLECT perimeter security system Integration with (per sensor) | Axis Communications AB Emdalavägen 14 SE-223 69 Lund Tel.: +46 46 272 18 00 Fax: +46 46 13 61 30 | Drivers Pack (ONVIF) | Ethernet | ACFA 6.7 DP 3.56 | ||||||||
KeyWatcher | Monitoring, control | INTELLECT Electronic Key Control Service (KeyWatcher), per panel |
| Low-level protocol | RS-232 | 6.8 | |||||||||
SafeKey | All SafeKey panel models | Monitoring, control | INTELLECT Electronic Key Control Service (SafeKey), per panel | SafeKey | Low-level protocol | Ethernet | 6.8 | ||||||||
All STX series controllers STX-2200 controller | Monitoring, control | INTELLECT Access Control Service (STX1000), per controller | GS Software | Low-level protocol | RS-232, RS-485, Ethernet | 6.8 | |||||||||
Symmetry | Amag Symmetry | Monitoring, control | INTELLECT Access Control Service (Amag Symmetry), per reader | AMAG Technology, Inc. | SOFT-SOFT | - | 6.9 | ||||||||
Nedap AEOS | Nedap AEOS Software | Monitoring, control | INTELLECT Access Control Service (Nedap AEOS Software), per door | Nedap N.V. Parallelweg 2 7141 DC Groenlo The Netherlands Tel.: +31 544 471 111 Email: info@nedap.com | SOFT-SOFT | - | 6.9 | ||||||||
Bosch BIS | Bosch BIS BIS Software version 4.8 | Monitoring, configuration, control. The FSA part of Bosch BIS is fully supported via the OPC Wrapper module | INTELLECT—Bosch BIS ACS integrationINTELLECT Access Control Service (Bosch BIS), per 1 connection to the BIS server | Robert Bosch GmbH | SOFT-SOFT | - | 6.9 |
...
Common name | Integrated hardware (name of devices) | Functionality | Name in price list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA Intellect version |
Suprema 2 | BioStation 2 BioEntry W FaceStation F2 (all models, with an option to receive temperature from Suprema Thermal Camera) X-Station 2 (all models, with an option to work with QR codes) CoreStation BioEntry P2 XPass 2 XPass S2 Any device with SDK v.2 support | Monitoring, control (configuration via BioStar 2) | INTELLECT Access Control Service "Suprema 2", per reader | Suprema www.supremainc.com | SDK | Ethernet | 6.5 |
HikVision | DS-K26x and DS-K28x series controllers, where x is the number of doors supported (for example, DS-K2602, DS-K2804). DS-KVx series сall panels, where x is the second part of the name of the call panel (for example, DS-KV8102-IP). DS-K1T605x, DS-K1T606x, DS-K1T671x, DS-K5603x access control terminals, where x is the version. All other HikVision terminals are also supported. | Monitoring, configuration, control | INTELLECT Access Control Service (HikVision), per reader | Hikvision USA | SDK | Ethernet, RS-485 | 6.5 |
MorphoAccess SIGMA Lite | All MorphoAccess SIGMA Lite series terminals | Monitoring, configuration, control | Intellect Access Control Service (Morpho Sigma Lite), per terminal | IDEMIA 2 Place Samuel de Champlain 92400Courbevoie France +33 (0)1 73 60 20 20 info@idemia.com | SDK | Ethernet | 6.6 |
Virdi | MCP-040 Controller The terminals of AC series: AC-7000, AC-5100, AC-2200, AC-2100, AC-2000, AC-1100, AC-6000 The terminals of UBio-X series: UBio-X Pro Lite, UBio-X Iris, UBio-X Slim, UBio-X Face, UBio-X Pro2, UBio-X Pro Control reader FOH02 | Monitoring, configuration, control | INTELLECT Access Control Service (Virdi), per controller | Union Community Co. Ltd | SDK | Ethernet | 6.7 |
BioSmart UniPass | UniPass controller PV-TS, PV-WM, and USB DCR-PV readers PV-WTC terminal | Monitoring, configuration, control | INTELLECT Access Control Service (BIOSMART - biometric identification), per controller | LLC "Prosoft-Biometrics" | low-level protocol | USB, Ethernet | 7.0 |
Dahua | All Dahua terminal models. ASA4214F and DHI-ASI7213X-T1 models were tested by AxxonSoft QA team | Monitoring, configuration, control | INTELLECT Access Control Service (Dahua), per terminal | Dahua Technology Co., Ltd. Tel.+86 571 8768 8883 Fax +86 571 8768 8815 overseas@dahuatech.com https://www.dahuasecurity.com | SDK | Ethernet | 6.9 |
BAS-IP | INTELLECT Access Control Service (BAS-IP) |
...
Common name | Integrated hardware (name of devices) | Functionality | Name in price list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA Intellect version |
Paradox | EVO48 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Paradox), per COM port | Paradox Security Systems http://www.paradox.com/ | low-level protocol | RS-232, USB | 5.3 |
FoxSec | FS9000 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Foxsec), per controller | FoxSec | low-level protocol | Ethernet | 5.2 |
ApolloSDK v.2 | AAN-100 | Monitoring, configuration, control | See detailed information in the Supported hardware and licensing of the Apollo SDK v.2 integration module section | AAM Systems | SDK | RS-232, Ethernet | - |
HID | EDGE ER40; VertX: v1000, v100, v200, v300, v2000, EVO | Monitoring, configuration, control | INTELLECT Access Control Service (HID VertX/Edge), per reader | HID Glogal http://www.hidglobal.com | SDK | Ethernet | - |
OnGuard 7.6 | Any Access Control, Fire Alarm or Intrusion Panel supported in OnGuard 7.6 | Monitoring, configuration (users only), control | INTELLECT Access Control and Fire Alarm Service (OnGuard), per reader INTELLECT Fire Alarm Service (OnGuard), per alarm panel | Lenel S2 https://www.lenel.com/ | SDK | Ethernet, RS-232 | 6.9 |
Honeywell Galaxy Dimension v.2 | Galaxy GD-48 Galaxy GD-96 Galaxy GD-264 Galaxy GD-520 DCM MAX4 | Monitoring, configuration, control | INTELLECT Access Control and Fire Alarm Service (Honeywell Galaxy Dimension), per COM port | Honeywell Systems Group Video and Access Control Solutions Aston Fields Road Whitehouse Industrial Estate Runcorn Cheshire WA7 3DL United Kingdom Tel: +44 (0)8448 000 235 Fax: + 44 (0)01928 754050 Email: sales.video.uk@honeywell.com www.security.honeywell.com | low-level protocol | RS-232, Ethernet | 5.0 |
Control readers
General | Integrated hardware (name of devices) | Name in price list |
---|---|---|
Documentation | Suprema BioMini * This control reader modules are installed automatically together with the corresponding ACS integration modules | Intellect — Control reader for visitor management system An unlimited number of control readers is also included in the Intellect Visitor Management System license |
...