Go to documentation repository
Page History
...
- Low-level protocol. The system developer presented events, reactions and equipment connection commands as the byte set, so the equipment can be directly connected to Intellect.
SDK—Software Development Kit. The system developer presented SDK, so the equipment can be directly connected to Intellect.
- Communication server (Program-driver). The system developer presented own driver (program layer between AxxonSoft software and hardware in which events, reactions, configuration commands and state request are built in) in order to connect the equipment. Install the third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. COM-server and OPC-server are examples of such programs.
- API—Application Programming Interface. The system developer presented an API for working with equipment through the built-in Web server, so the equipment can be directly connected to Intellect.
SOFT-SOFT. The system developer presented an API for using its commands in Intellect and vice versa in order to connect the equipment. Install the full version of third-party software and configure its interaction with Intellect in order to connect the equipment to Intellect. Database synchronization is a way of SOFT-SOFT integration on the level of joint using of one database by two software packages, e.g. to access the event log.
Info title Note Hardware connection interface is not specified for soft-soft integrations because ACFA Intellect connects with 3d party software and not with the devices directly. Please contact the 3d party software vendor in order to get information about the hardware connection interface.
Universal protocol integration: OPC, SNMP, BACnet, and Modbus. OPC and BACnet are industry standards. The system developer makes OPS-server and BACnet-server implementation for its devices and sends data over OPC or BACnet protocols. Intellect is the client for such servers and it gets data (events, reactions, configuration commands, etc.). SNMP is a network protocol used to monitor some devices. The list of some hardware connected to Intellect over universal protocols is specified in the Systems connected by universal protocols section.
- Drivers Pack. An equipment was integrated using one of the above methods via Axxon Drivers Pack. When using this integration method, it is necessary to install not only ACFA Intellect (version 6.4 and higher), but also the Drivers Pack (version 3.49 and higher).
...
Common name | Integrated hardware (name of devices) | Functionality | Name in price list | Information on manufacturer | Way of integration | Hardware connection interface | ACFA Intellect version |
Noder | EWE4 controller EE12 controller EW2 controller EWE2 controller Reader MD-R / W Reader with MDK-R keypad Expansion board for elevator control IO16RS Converter RS -> Wiegand | Monitoring, configuration, control | INTELLECT Access Control Service (Noder EW2/EWE2), per controller INTELLECT Access Control Service (Noder for KONE DCS), per elevator group INTELLECT Access Control Service (Noder EWE4), per controller INTELLECT Access Control Service (Noder EE12), per controller | low-level protocol | Ethernet | 6.9.4500 | |
Castle | Pro, Pro4, RS, ES, EP, EP2, EP4 | Monitoring, configuration, control | Intellect Access Control Service (Castle), per IP | Castle Creations | communication server | USB-RS485, Ethernet | - |
Honeywell N-1000 (past Northern Computers) | N-1000 | Monitoring, control | INTELLECT Access Control Service (Honeywell N-1000-IV), per COMport | Honeywell Systems Group Video and Access Control Solutions www.security.honeywell.com | low-level protocol | RS-232 | - |
Sigur | EAll Sigur access controllers, including E100, E300H, R500D4/E500D4, R500/E500, E500U/R500U, R900I/E900I, E900U/R900U, E2, E4, etc. | Monitoring, configuration, control | INTELLECT Access Control Service (Sphinx), per access controller | «PromAvtomatika Service» | SOFT-SOFT | - | - |
SALTO | CU50ENSVN, GateWay, Encoder | Monitoring, configuration, control | INTELLECT SALTO integration module | Salto www.saltosystems.com | SOFT-SOFT | - | - |
ZK Teco | C3-100, C3-200, C3-400 | Monitoring, configuration, control | INTELLECT Access Control Service (ZKAccess), per door | ZKTeco | SDK | Ethernet, RS485 | 6.2 |
Schindler elevator controller | Monitoring, configuration | INTELLECT Access Control Service (Schindler Port), per controller | Schindler Management Ltd | SDK | Ethernet | 6.8 | |
Unicard U700 | U700 controller | Monitoring, configuration, control | INTELLECT Access Control Service (UNICARD), per access control point | Unicard SA | low-level protocol | Ethernet | 6.2 |
Axis | A1001 | Monitoring, control | INTELLECT perimeter security system Integration with (per sensor) | Axis Communications AB Emdalavägen 14 SE-223 69 Lund Tel.: +46 46 272 18 00 Fax: +46 46 13 61 30 | Drivers Pack (ONVIF) | Ethernet | ACFA 6.7 DP 3.56 |
KeyWatcher | Monitoring, control | INTELLECT Electronic Key Control Service (KeyWatcher), per panel |
| Low-level protocol | RS-232 | 6.8 | |
SafeKey | All SafeKey panel models | Monitoring, control | INTELLECT Electronic Key Control Service (SafeKey), per panel | SafeKey | Low-level protocol | Ethernet | 6.8 |
All STX series controllers STX-2200 controller | Monitoring, control | INTELLECT Access Control Service (STX1000), per controller | GS Software | Low-level protocol | RS-232, RS-485, Ethernet | 6.8 | |
Symmetry | Amag Symmetry | Monitoring, control | INTELLECT Access Control Service (Amag Symmetry), per reader | AMAG Technology, Inc. | SOFT-SOFT | - | 6.9 |
Nedap AEOS | Nedap AEOS Software | Monitoring, control | INTELLECT Access Control Service (Nedap AEOS Software), per door | Nedap N.V. Parallelweg 2 7141 DC Groenlo The Netherlands Tel.: +31 544 471 111 Email: info@nedap.com | SOFT-SOFT | - | 6.9 |
Bosch BIS | Bosch BIS Software version 4.8 | Monitoring, configuration, control. The FSA part of Bosch BIS is fully supported via the OPC Wrapper module | INTELLECT—Bosch BIS ACS integration | Robert Bosch GmbH | SOFT-SOFT | - | 6.9 |
...