Settings panel of the Surveillance object object is given on the figure.

Description of the Surveillance object object settings panel elements is given in the table.

#

Parameter

Method for setting the parameter value

Description

Type

Default value

Value range

1

Identifier

Automatically

Shows the identification number of the Surveillance object object in the system

Nonnegative integer

-

Depends on number of Surveillance object objects in the system

2

Parameter

Enter the value in the field

Shows the name of the Surveillance object object in the system

Latin, Cyrillic letters and service characters

Surveillance object

A line representing a sequence of any symbols
(letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

ATM-Intellect Pro

Is selected in the list

Assigns the parent ATM-Intellect Pro object for the Surveillance object object

Names of Surveillance object objects registered in the system

Name of the parent ATM-Intellect Pro object

Depends on the number of the ATM-Intellect Pro objects in the system.

4

ID

Enter the value in the field

Sets the unique ID number of the ATM machine

Nonnegative integer

386

>=0

5

TCP port (UPS)

Enter the value in the field

Sets the port on which to "listen" for UPS messages

Nonnegative integer

8888

from 1 to 65535

6

Transmitting...

Click the button

Opens a dialog box with settings for configuring the communication between ATM-Intellect Pro and ATM-Intellect Workstation

-

-

-

7Printer...Click the buttonOpens a dialog box for configuration of ATM receipts captioning.---

8

Cameras

Using the Cameras... button

Displays the list of cameras whose state and archives are monitored by ATM-Intellect Pro and operating with which shall be available from ATM-Intellect software interface.

-

-

-

89

Cameras...

Click the button

Opens a dialog box for adding cameras for monitoring their status

-

-

-

910

Sensors

Using the Add, Edit and Delete buttons

Displays IDs and types of sensors whose state is monitored by ATM-Intellect Pro and on whose triggering video data are sent to the ATM-Intellect Workstation.

-

-

-

1011

temperature sensor set

Is set in a checkbox

Specifies if monitoring to ensure that temperatures do not deviate from an allowed range is performed using temperature sensors

Boolean

False

True - True – temperature sensors set is in use

False - False – temperature sensors set is not in use

1112

Add...

Click the button

Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering

-

-

-

1213

Edit...

Click the button

Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor

-

-

-

1314

Delete

Click the button

Deletes sensor from the list

-

-

-

Titles group

1415

Displaying time (sec.)

Is selected in the list

Sets duration of captions displaying on video image beginning at the moment of corresponding event appearing from the secured object (ATM)

Seconds

10

5, 10, 15, 20, 30, 45, 60, 90, 120, 20015

16

Date and time

Is set in a checkbox

Specifies if it is necessary to include event date and time into the captions

Boolean

True

Yes - True – date and time are included into the captions

No - False – date and time are not  included into the captions

1617

ATM number

Is set in a checkbox

Specifies if it is necessary to include into the captions the number of ATM from which the event came

Boolean

True

Yes - True – ATM number is included into the captions

No - False – ATM number is not included into the captions

1718

card Card status

Is set in a checkbox

Specifies if it is necessary to include data on card status into the captions

Boolean

True

Yes - True – card status is included into the captions

No - False – card status is not included into the captions

1819

amountAmount

Is set in a checkbox

Specifies if it is necessary to include operation amount into the captions

Boolean

True

Yes - True – amount is included into the captions

No - False – amount is not included into the captions

1920

card Card number

Is set in a checkbox

Specifies if it is necessary to include card number into the captions

Boolean

True

Yes - True – ATM number is included into the captions

No - False – ATM number is not included into the captions

2021

maskMask

Is set in a checkbox

Specifies if it is necessary to apply mask to a card number when displaying in in the captions

Boolean

True

Yes - True – card number is masked

No - False – card number is fully displayed

...