Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Description of events of the Grabber object.

Event

Description

"+12V"

Voltage error +12V.

"+3.3V"

Voltage error +3.3V.

"+5V"

Voltage error +5V.

"-12V"

Voltage error -12V.

"-5V"

Voltage error -5V.

"CPU_FAN"

Number of ventilator rotations.

"CPU_TEMP"

Temperature of processor.

"SYS_TEMP"

Temperature of MB chipset.

"UPS_COMMLOST"

Connection lost.

"UPS_FATAL_ERROR"

Error of connection.

"UPS_LOWBATT"

Battery low.

"UPS_ONBATT"

Switch to battery supply.

"UPS_ONLINE"

Restoring the main supply.

"UPS_REPLACEBATT"

Battery changing is required.

"UPS_SHUTTING"

Shutdown.

"VCORE"

Voltage of processor core.

"AUDIO_SIG_LOST "

Sound lost

"CONNECT_FAIL"

Connection error

"CONNECT_OK "

Connected

"NETWORK_FAILURE "

Connection lost

"STATE_CONNECTED "

Connection restored

Operator format to describe actions with the video capture device is:

...

List of commands and parameters for the Grabber object is presented in the following table:

Commandcommand description

Parameters

Description of parameters

"SETUP" – sets parameters of video capture device.

chan<>

Number of PCI slot (0,1,2,…,32).

mode<>

Speed of grabber/digitising (0 – maximal, 1 – average, 2 – minimal).

resolution<>

Resolution (0– standard, frame quarter (384x288); 1 – high, half-frame (768x288); 2 – maximal frame (768x576)).

format<>

Format of video signal (PAL, NTSC).

drives<>

Disks for video archive record (DRIVE1:\, DRIVE2:\ … DRIVEN:\).

cams<>

Number of connected video cameras

auth<>

 


ip<>

IP-address of video input network card

name<>

Name of object.

flags <>

Flags.

ip_port<>

IP-port.

password<>

Password.

type<>

Type of digitising.

username<>

Login.

watchdog<>

WatchDog shutdown (0 –disabled, 1 – enabled).

"SET_DRIVES" – sets disks for video archive record.

drives<>

Disks for video archive record.

"MUX1_OFF" – disables video output through the analog output 1.

-

-

"MUX2_OFF" - disables video output through the analog output 2.

-

-

"MUX3_OFF" - disables video output through the analog output 3.

-

-

"SET_IPINT_PARAM" – Sets (change) parameters of IP-device. Reaction allows changing of IP-device settings not entering its web-interface.

Note. For reaction operation it is required to enable the mode of multi-flow video signal - see. Administrator's Guide, sectionConfiguration of multistream video, andAppendix 2. Defining param_id and param_value values for SET_IPINT_PARAM reaction

param_id<>

Name of parameter. Set of parameters for each camera is individual - see Appendix 2. Defining param_id and param_value values for SET_IPINT_PARAM reaction

param_value<>

Value of parameter. Set of parameters for each camera is individual - see Appendix 2. Defining param_id and param_value values for SET_IPINT_PARAM reaction

cam_id<>

Camera ID in the Intellect software package.

vstream_id<>

Number of video-flow (optional parameter). Is given by “Number of camera”.”Number of flow”, for example 1.1, 1.2.

Properties of the GRABBER object are shown in the table.

Properties of the GRABBER object

Description of properties

ID<>

Object ID.

PARENT_ID<>

Number of video capture device.

Examples of using events and reactions of the Video capture Device object:

...