Go to documentation repository
Page History
Section | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Sensor status indication
Identification of the sensor symbol icon on the Map depends on the current operating mode and sensor status, as well as the type of intrusion sensor. The The sensor is always in 2 states simultaneously, therefore two states at the same time, so its icon on the map blinks and changes once in a certain periodMap is always blinking, and the state icons change in equal time intervals. State icons for different annunciator sensor types are shown below. In the dbo.state column, the state The state written to the dbo.STATES database is given in the dbo.state column.
Heat sensor:
Glass sensor:
...
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Glass sensor:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Ceiling sensor:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Window sensor:
Infrared sensor:
Smoke sensor:
Hermetic contact:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Infrared sensor:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Smoke sensor:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Reed sensor:
State | dbo.state | Icon on the Map |
---|---|---|
Armed | ARMED | |
Disarmed | DISARMED | |
Alarm | ALARMED | * |
Alarm confirmed | CONFIRMED | |
Connection lost | DETACHED_DISARM | * |
Normal (off) | OFF | |
Active (on) | ON |
Info | ||
---|---|---|
| ||
Reference * means that the image of the given icon is blinking. |
For a Sensor security device type with the Circuit closure operation mode, an alarm event is generated in case of the sensor closure. For a Sensor security device type with the Circuit interruption operation mode, an alarm event is generated in case of the sensor interruptionSensor type security devices operated on the basis of circuit closure, interpret any sensor closure as an alarm event, whereas devices operated on the basis of circuit interruption, identify any sensor interruption as an alarm event.
If the Sensor is armed, then at the Sensor switching on/off the "Alarm" event appears depending is generated in case of the sensor on/off switch depending on the specified alarm mode setting (see the see Creating and configuring the Sensor system object section of the Installing and configuring security system components guide). If the Sensor is disarmed, then the "Closed"/"Opened" events appear correspondinglyare generated correspondingly. If the connection between the Intellect and the sensor is lost, the "Connection lost" event will be generated.
Info | ||
---|---|---|
| ||
When an alarm is registered by any sensor, connected through IP-device the Samsung SNC-M300P IP device, Sensor symbol with 1channel sensor icon with 1 channel number is activated (the given IPdevice IP device supports two connection channels of sensors). |
...
The sensor is operated via the feature function menu of the given sensor symbol icon shown on the Map.
The feature You can access the function menu of the sensor is called up by a right mouse click on -clicking the corresponding sensor symbolicon.
The feature menu of the sensor provides access to various operating functions of the sensor.
Function menu item | Function | Comments |
---|---|---|
Sensor No./Date and time of the latest status modification | Shows the identifier of the selected sensor in the program, the current status of the sensor, the date and time of the latest sensor status modification |
See Using sensors |
Arm | Arms the sensor |
Confirm | Confirms alarm event registration by the sensor |
Disarm | Disarms the sensor |