Configure the Suprema RealScan control reader in the Intellect software as follows:

  1. Connect the reader to a Server, download and install driver from the manufacturer's official web site.

    InfotitleNote

    Registration on the manufacturer's website is required for the driver download.

  2. Create the Suprema RealScan object based on the Computer object on the Hardware tab of the System Settings dialog box.
    Image RemovedImage Added

  3. Unset Uncheck the Automatic Calibrate  check Calibrate check box (1) if it is necessary to disable the automatic calibration of the reader.

    Info
    titleNote

    It is recommended not to unset this check box.


  4. In the Sensitivity Level drop-down list (2) select the sensitivity level:

    • Normal - average sensitivity.

    • Hight High - high sensitivity.

    • Higher - the highest sensitivity.

    • Disabled - disabled.

  5. In the Security Level drop-down list (3) select the fingerprint verification quality level:

    • Lowest (1/1000) - the lowest level.

    • Low (1/10 000) - low level.

    • Normal (1/100 000) - average level.

    • High - (1/1 000 000) - high level.

    • Highest (1/10 000 000) - the highest level.

  6. In the Region In field (4) specify the input region.

  7. In the Region Out field (5) specify the output region.

  8. Click Apply (6) to save the settings.

To use the connected Suprema RealScan control reader for enrolling fingerprints in Access Manager, select this reader while configuring the Access Manager – see the Selecting control readers in the Access Manager section of the Access Manager Module Settings and Operation Guide.Important!
Info
titleNote.
title
Note
  • The Suprema RealScan control reader is to be used only with the Suprema 2 integration module – see Suprema 2 Settings Guide.


Note
titleAttention!

The module requires the 32-bit version of the Microsoft Visual C++ 2008 redistributable package to be installed. If this component is not installed in your system, use the redist/en/x86/vc90redist.exe installer provided in the ACFA Intellect installation package.

Configuring Suprema RealScan control reader connection in the Intellect software is completed.