The settings panel of the SIP-panel object is shown in the figurefigures below.
The description of the Table describes the setting parameters of the SIP-panel interface object settings is shown in the table.
№ | Parameter | Method for |
setting the parameter value | Parameter description |
Representation | Default value |
1
The Identification number field
Automatically
Positive integer
-
2
The Name field
Type-in the value in the field
Assigns the name to the SIP-panel object
Latin, Cyrillic and service characters
Display manager
A line containing a sequence of any symbols (letters, digits, service, characters apart from > and < symbols), non case-sensitive
Number of symbols – from 1 to 60
3
The Disable checkbox
Set the chechbox
Shows the status (enabled or disabled) of the SIP-panel object in the system
Boolean type
No
Value range | ||||||
The Position group | ||||||
1 | X | Enter the value into |
No – the SIP-panel object is enabled and is in use
4
The Display dropdown list
Select from the list
Assigns the parent Display object, to which the given SIP-panel object refers
Name of the Display objects registered in the system
Name of the parent Display object
Depends on the number of the Display objects in the system
5
The X filed
the field | Sets the X coordinate in the |
horizontal axis for the upper left corner of the SIP-panel interface |
window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
Y |
Enter the value |
into the field | Sets the Y coordinate in the |
vertical axis for the upper left corner of the SIP-panel interface |
window | % of the screen height | - | From 0 to M*100, where M is the number of the installed monitors |
2 |
W |
Enter the value |
into the field | Sets the |
width of the SIP-panel interface |
window | % of the screen width | - | From 0 to M*100, where M is the number of the installed monitors |
H |
Enter the value |
into the field | Sets the |
height of the SIP-panel interface |
window | % of the screen |
width | - | From 0 to M*100, where M is the number of |
the installed monitors | ||||||
3 | The × button | Click the button | Opens a test window for changing the coordinates of the SIP-panel interface window | - | - | - |
4 | Monitor | Select the value from |
the list | Sets the |
number of the monitor in the system for which the coordinates are |
specified |
Numbers of the monitors in |
OS | 1 | From 1 to 16 |
The Basic settings tab.
Table describes the parameters of the Basic settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | Terminal | Select the value from |
the list | Sets the SIP-terminal object, which SIP-devices use the SIP |
-panel | Name of the SIP |
-panel objects registered in the system | - | Depends on the number of |
the SIP-terminal objects in the system |
2 |
Monitor |
Select |
the value from the list | Sets the the Monitor object corresponding to the Video |
surveillance monitor to which the video cameras associated with the corresponding SIP-devices are added |
Name of the Monitor objects registered in the system | - | Depends on the number of the Monitor objects in the system |
10
The Advanced settings tab.
Table describes the parameters of the Advanced settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Interface behavior group | ||||||
1 |
Display only when calling |
Set the checkbox |
Displays the SIP-panel |
only |
when calling | Boolean type |
Clear |
Set—the SIP-panel is only displayed |
when calling Clear— |
the SIP-panel is always displayed |
2 |
New calls to the end |
Set the checkbox | Enables adding new calls to the end of the list |
Boolean type |
Clear |
Set—new calls are added to the end of the list |
Clear—new calls are added to the top of the list |
3 |
Disable keypress sound |
Set the checkbox |
Disables keypress sound on the SIP-panel | Boolean type |
Clear |
Set—keypress sound disabled |
Clear—keypress sound is enabled | ||||||
4 | Maximize screen on call | Set the checkbox | Enables automatic display switching on call | Boolean type | Clear | Set—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen to which the SIP-panel is added is displayed automatically Clear—when a call is made to the SIP-terminal that corresponds to the SIP-panel, the screen is not displayed automatically |
5 | Calls to unknown users | Set the checkbox | Enables the option to call unknown users Note. Unknown user is a number that is present in the SIP-terminal, but not in the address book of the current SIP-operator | Boolean type | Set | Set—calls to unknown users are allowed Clear—calls to unknown users are not allowed |
6 | Switch to incoming | Set the checkbox | Automatically switches to the tab of the SIP-panel with the incoming calls, which occurs with incoming calls or call on hold | Boolean type | Set | Set—automatic switch to the tab with incoming calls is enabled Clear—automatic switch to the tab with incoming calls is disabled |
The Interface elements group | ||||||
7 | Dial pad | Set the checkbox | Displays the dial pad in the interface | Boolean type | Set | Set—the dial pad is displayed Clear—the dial pad is hidden |
Caption | Set the checkbox | Displays the tab names in the interface. When disabled, only the Call tab will be displayed without displaying the name | Boolean type | Set | Set—the tab names are displayed Clear—only the Call tab is displayed without displaying the name | |
Archive | Set the checkbox | Displays the Archive tab in the interface | Boolean type | Set | Set—the Archive tab is displayed Clear—the Archive tab is hidden | |
Call control buttons | Set the checkbox | Displays the buttons at the bottom of the panel to control a call | Boolean type | Set | Set—call control buttons are displayed Clear—call control buttons are hidden |
The Operator settings tab.
Table describes the parameters of the Operator settings tab.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Operators table | Select the value in the column | Sets the list of the SIP-operators who can work with this SIP-panel | - | - | - |
Number | Select the value from the list | Selects a SIP-operator identifier | Identifiers of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
Subscriber | Select the value from the list | Selects a SIP-operator number | Numbers of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
Name | Select the value from the list | Selects a SIP-operator name in Intellect | Names of the SIP-operator objects registered in the system | - | Depends on the number of the SIP-operator objects in the system | |
2 | All | Click the button | Adds all existing SIP-operators to the table | - | - | - |
3 | Range | Click the button | Opens the Add operators window to add multiple SIP-operators | - | - | - |
4 | Default | Select the value from the list | Sets the default SIP-operator | - | Select on start | Select on start—when you first start the SIP-panel, it is necessary to select the appropriate SIP-operator in the authorization window. Next time you will be logged in under the previously selected SIP-operator User rights—you will log into the SIP-panel as the SIP-operator that is linked to the Intellect user rights. You should also be logged into Intellect with the corresponding user rights SIP-operator from the list—logging into the SIP-panel will be made at once as the selected SIP-operator. Depends on the number of the SIP-operator objects in the system |