The requirements for cameras that will work with the the Fire detection module are follows: and Smoke detection modules are shown in the following table.

It's

Camera

  • Resolution is not less than 640x480.
  • FPS: any, 1 by default
    • It is recommended to use color cameras.
    Quality of recognition can be worse while using
    • With black and white cameras

    Object images

    • Fire area is not less than 10% from the frame area.
    Lightning
    • Any

    Hardware requirements are as follows:

    ...

    • , the recognition quality may be much worse
    • Resolution should be at least 640x360 pixels
    • Number of frames: the response rate of the detection module depends on the number of frames per second, by default, it is 1 per every 10 seconds (in most cases, it is enough to detect a fire/smoke that lasts more than 1 minute)
    Lighting
    • Fire/smoke should be visually separated from the background

    Object images

    • The minimum area of fire/smoke in the frame depends on the neural network used. For a standard neural network (see Configuring the Fire detection and Smoke detection modules), the area of fire/smoke should be at least 10% of the frame. In some cases, when the fire is well contained, it may be sufficient for a detection tool that the width/height of the fire zone is 1-3% of the width/height of the frame.


    Note
    titleAttention!