Go to documentation repository
Page History
...
Info | ||
---|---|---|
| ||
The ENDTIME and BEGINTIME syntax is described in Get archive contents section. |
Note | ||
---|---|---|
| ||
If ENDTIME < BEGINTIME in the request, then the events in the response will be sorted by time in ascending order. If ENDTIME > BEGINTIME, then the events will be sorted in descending order. |
GET http://IP-Address:port/prefix/archive/events/alerts/{HOSTNAME}/{ENDTIME}/{BEGINTIME} - get alarms from a certain Server.
...
Tip |
---|
{VIDEOSOURCEID} - three-component source endpoint ID (see Get list of video sources (cameras)cameras and information about them). For instance, "SERVER1/DeviceIpint.3/SourceEndpoint.video:0:0". |
...
Parameter | Required | Description |
---|---|---|
limit | No | The limit of alarms in the response. If not specified, it is equal to 100 by default. |
offset | No | The results offset by the specified number. For example, if a query with offset=0 returned 100 results, then in order to get the next results, it is necessary to run a query with offset=100. If the second query returned 250 results, then in order to get the next results, it is necessary to run a query with offset=350, etc. |
limit_to_archive | No | Is available starting with Axxon Next 4.4.1.9150. If limit_to_archive=1, then the response will return the events only from the accessible part of the archive (see Configuring access restrictions to older footage). |
archive | No | Is available starting with Axxon Next 4.4.1.9150. The name of the archive from the request to receive the list of archives (see Get archive contents). |
Sample request:
GET http://127.0.0.1:80/archive/events/alerts/Server1/past/future?limit=50&offset=0
...
Parameter | Description |
---|---|
raisedAt | Field raisedAt is not unique so it might be necessary to skip the previously received alarms starting from the search interval. |
reasons | Possible values of the reasons array: armed, disarmed, userAlert, ruleAlert, videoDetector, audioDetector, ray. |
severity | Possible values of the severity field: unclassified, false, notice, warning, alarm. |
initiator | Possible values of the initiator field:
|
...