For the precise tracking of moving objectsthe object under observation, you must calibrate PTZ cameras by mapping at least six PTZ positions to points in the field of view of each panoramic camera.
The more positions you map, the more precisely the PTZ camera is able to follow moving objects. It is recommended to map eight or more points.
...
should calibrate the telemetry device by matching at least four telemetry device positions with the frame points of each overview camera.
Note | ||
---|---|---|
| ||
The recommended number of points that should be set is 4-10. If you add more points, the algorithm will be configured more precisely. However, this may increase the chance that some of the points are set up incorrectly, which may cause the decrease of the operation quality. The points set in the calibration setting should not be on the same line for both the overview and the PTZ camera. It is recommended to set the points for both cameras so that they evenly cover the entire frame. The calibration points should be set on the same surface (floor, ground). It is not recommended to set the points on different surfaces (for example, when some points are on the ground, and other points are on a tree, etc.). |
To calibrate the telemetry device, do the following:
- Select the overview camera from the list (see Linking panoramic cameras to a PTZ camera).
- Focus the PTZ camera on any point.
To To do this, in the preview window click the button and change the lens orientation, leftorientation of the lens in one of the following ways:- Left-click on the frame and
- holding the
- button,
- move the
- mouse cursor in the
- required direction.
- Use the Point&Click function (see Control using Point&Click).
Left-click to add a point in to the frame of the panoramic overview camera toward to which the PTZ camera is currently oriented.
...
title | Attention! |
---|
Note | ||
---|---|---|
|
...
Set calibration points on the same plane (floor, ground). Do not set the points on different planes (for example, when some are on the ground while others are on a tree, etc.).
The |
...
object under observation should be inside the |
...
frame of |
...
the PTZ camera. |
4. Repeat
...
the process
...
to set at least
...
4 points.
5. Repeat the process for all
...
overview cameras (
...
select
...
the camera by clicking in the list of the overview cameras).
...
6. Click the Apply button to save the calibration points
...
.
Calibration of the telemetry device is complete.
It is recommended to After setup is complete, we recommend that you perform a calibration check after calibration is complete. To do this, do the following:
- Click the to the right of the preview for that PTZ window of the overview camera. button
Click on different points in the image of the overview camera
's field of view. If the PTZ camera is positioned correctly,
it needs nothe calibration is correct.
Info | ||
---|---|---|
| ||
To delete the calibration points, click the button. |
...