The Telemetry control panel object is used to register and configure the Universal PTZ control panel interface object in Axxon PSIM that isused to control the PTZ devices.

The settings panel of the Telemetry control panel object is shown in the figure.

 Image Modified

The table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Telemetry control panel object.

Symbols used.1 or more.Type-in Specifies . symbols apart from symbols not sensitive symbols – .Checkbox is setSets the status of the .-Yes is not in useNo – the is in use.Is selected in Display object for the given . Display .. Coordinates Is selected in The in OS specifyingNumbers of monitors-Type-in . X Telemetry on ..   30 is installed.Type-in . coordinate in the Y vertical axis for the upper left corner Telemetry control panel on the screen. height.30 0 is installed.Type-in . the width Telemetry . width.   - 18 is installed.Type-in . Telemetry .- is installed. settings--- window’s Checkbox is set Telemetry panelYesYesTelemetry No – forbid moving Telemetry control panelDisplays Telemetry control panelYes – display Telemetry .No – do not Telemetry .Is selected in Telemetry for Telemetry Low – Telemetry control . – control over Telemetry Standard High Standard - control over Telemetry High . - control over Telemetry placeEnables saving Shows ..The list ..Click Shows Telemetry -. specified --- specified .---.---.---

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Telemetry control panel object in the system

Sequence of numbers

-

Digits, letters, periods, hyphen, dash, and underscore

NA

A line containing numbers, letters, periods, hyphen, dash, and underscore

Depends on the number of the Telemetry control panel objects in the system

2

The Name*
field

Enter the value in the field

Sets the name of the Telemetry control panel object in the system

Latin alphabet, Cyrillic, digits and service characters

Telemetry control panel

A line containing a sequence of any

characters (letters, digits, service characters

except > and <

characters),

case-

insensitive.

Number of

charactersfrom 1 to 60

3

The Disable

checkbox

Set the checkbox

Disables the Telemetry control panel object in the video surveillance system

with distributed architecture

Boolean type

Clear

Setthe Telemetry control panel object is disabled and

isn't used

Clearthe Telemetry control panel object is enabled and

used

4

The Display


drop-down list

Select the value from the list

Sets the Display parent

object in the system with distributed architecture to which the given Telemetry control panel object

belongs

Names of the Display objects registered in the system

Name of the Display parent

object

Depends on the number of the Display objects in the system

The
 Output window group

5

The Monitor


drop-down list

Select the value from

the list

Sets the number of the monitor

for which the coordinates are

set

Number of the monitor in OS

1

From 1

to 16

6

The X field

Enter the value in the field

Sets the X coordinate in the

horizontal axis for the upper left corner of the

telemetry control panel

 window on the screen

% of the screen width

 30

From 0 to M*100, where M

is the number of the installed monitors

7

Y

The W fieldEnter
the value in the field
Sets the
width of the
telemetry control panel window% of the screen
width
NAFrom
18 to M*100, where M
is the number of the installed monitors

8

W

The Y field

Enter

the value in the field

Sets

the Y coordinate in the vertical axis for the upper left corner of the

telemetry control panel

 window on the screen

% of the screen

height

30

From

0 to M*100, where M

is the number of the installed monitors

9

The H field

Enter the value in the field

Sets the height of the

telemetry control panel window

% of the screen height

NA

From 34 to M*100, where M

is the number of the installed monitors

10

The Current

coordinates* Image Added button

Click the button

Sets the current coordinates of the Telemetry control panel object in the X, Y, W, and H fields

NA
NA
NA

11

The Allow

window moving

checkbox

Set the checkbox

Allows moving the

 telemetry control panel using the mouse

Boolean type

Set

Setallow moving the

telemetry control panel

 window

Clear—disable moving the telemetry control panel window

12

The Half-transparent window

Checkbox is set

checkbox

Set the checkbox

Sets the display of the telemetry control panel in

the half-transparent

way

Boolean type

Yes

Set

Setdisplay

the half-transparent

telemetry control panel

 window

Cleardon't display the half-transparent

telemetry control panel

 window

Out of the group

13

The Priority


drop-down list

Select the value from

the list

Sets the priority of

the PTZ devices' control

Names of the priorities

to control the PTZ devices

Low 

  • Forbidden
  • —control of the PTZ device using the telemetry control panel is forbidden
  • ;
  • Low
  •  prioritycontrol of the PTZ device using the
  •  telemetry control panel is performed after it controls the devices with
  • normal or
  • high priority;
  • Normal prioritycontrol of the PTZ device using the
  •  telemetry control panel is performed after it controls devices with
  • high priority
  • ;
  • High
  •  prioritycontrol of the PTZ device using the
  •  telemetry control panel is performed in the first
  • order

14

The Allow presets

Checkbox is set


checkbox

Set the checkbox

Allows saving the position of the PTZ device in the

presets

Boolean type

Yes

Yes – presets saving is enabled.

No  – presets saving is disabled

15

Allow hotkeys

Checkbox is set

Enables Telemetry control using a keyboard

Boolean type

No

Yes– keyboard can be used for Telemetry control

No – keyboard hotkeys are not used for Telemetry control  

16

Set

Set—allow saving the position of the PTZ device in the presets

Clear—disable saving the position of the PTZ device in the presets

15

The Allow hotkeys
checkbox

Set the checkbox

Enables the PTZ device control using the keyboard

Boolean type

Clear

Setkeyboard can be used to control the PTZ device

Clearkeyboard hotkeys cannot be used to control the PTZ device

16

The Available cameras with telemetry control
field

Automatically

Specifies the cameras with the PTZ devices

Names of the Camera objects registered in the system

List of all Camera objects registered in the system

Depends on the number of the PTZ devices

in the system with distributed architecture

17

The Selected cameras

 field

Select by clicking the

arrow keys

Sets the cameras with the PTZ devices that can be controlled using the

telemetry control panel

-

Names of the Camera objects registered in the system

NA

Depends on the number of the PTZ devices

in the system with distributed architecture

18

The One to the right* Image Added button

Click the button

Moves

the selected PTZ device from the Available cameras with telemetry control list to the Selected cameras list

NA
NA
NA

19

The One to the left* Image Added button

Click the button

Moves

the selected PTZ device from the Selected cameras list to the Available cameras with telemetry control list

NA
NA
NA

20

The All to the right*Image Added button

Click the button

Moves all PTZ devices from the Available cameras with telemetry control list to the Selected cameras list

NA
NA
NA

21

The All to the left* Image Added button

Click the button

Moves all PTZ devices from the Selected cameras list to the Available cameras with telemetry control list

NA
NA
NA

*  The name Name of the element is not isn't displayed in the settings panel of the given object

...