Axxon PSIM's core interacts with functional modules (third party information systems) according to the following connection parameters:

  1. Port number.
    1. For the video subsystem: 900.

    2. For the Interface IIDK object: 1030.

    3. For ATM objects: 1009.

      Info
      titleNote.

      1030 (IIDK) port can be in use to connect ATMs (ATM) (not only 1009 port) - in this case the ATM object will be marked with red cross in the hardware tree. For this the IIDK Interface object is to be created in the hardware tree.


  2. The IP address of the computer that is running Axxon PSIM's core.

  3. ID (the connection object ID).

...

Info
titleNote:
If an MDL file exists (see Section Creating MDL files), the connection to Axxon PSIM's core does not require creating the IIDK Interface object in the system. The connection ID passed is an empty string (in other words, the ID is "").

...