In case the POS-server abnormally disconnects from the MixForward utility, is can be re-connected.

...

  1. XML-data receipt via TCP protocol is expected ;(1).
  2. The Keep connection checkbox is set checked (2).

Image Modified

If the Keep connection option is enabled, the POS-server registers the connection of the utility and determines the time interval since the last data transfer. If the data has not been received for more than 30 seconds, the POS-server breaks the connection and re-establishes it again.

...

Note
titleImportant!

If there is connection loss or errors when sending data from MixForward utility in POS PSIM, then the Keep connection checkbox is to be set unchecked.

To close the MixForward utility and stop the data package routing process, select Close in the File menu.

Info
titleNote
Clicking the  button button in the upper right corner of the window closes the window, but does not stop the routing process.