Purpose of document

HoneyWell N-1000 integration module . Configuration and operation guide Settings Guide is a reference and information manual. It is meant for configuration specialists and operators of HoneyWell N-1000 module. This module is a part of access control system that is carried out on the basis of ACFA Axxon PSIM software package.

The following information is performed in this Guide:

  1. General information about HoneyWell N-1000 integration module;.
  2. Setting up HoneyWell N-1000 integration module;.
  3. Working with HoneyWell N-1000 integration module.

General information about

...

the HoneyWell N1000 integration module

The HoneyWell N1000 integration module is a component of ACS that is carried out on the basis of ACFA Axxon PSIM software package and is for realization of the following functions:

  1. HoneyWell N-1000 ACS configuration (Honeywell Security is a manufacturer);.
  2. Interaction of HoneyWell N-1000 ACS with ACFA Axxon PSIM software package(configuration, monitoring, control).  

...

N-1000-III and N-1000-IV HoneyWell N-1000 ACS controllers are integrated intoACFA Axxon PSIM software package. These controllers are for ACS construction on the objects of medium size.

Technical features of N-1000-III and N-1000-IV controllers are given in the table.

Feature

N-1000-III

N-1000-IV

Number of supported readers/keyboards

2/2

4/2 or 0/4

Maximum number of users, persons

5 000 (with 25 000 resolution)

5 000 (with 25 000 resolution)

Storage, events capacity

10 200

10 200

Number of relay outputs

4

4 (with 24 resolution)

Number of alarm inputs

16 (normally closed resistive/dead contacts)

16 (normally closed/dead contacts)

...


Before setting up HoneyWell N-1000 integration module do the following:

  1. Install HoneyWell N-1000 ACS hardware on secured object (see reference documentation for HoneyWell N-1000 ACS).
  2. Connect HoneyWell N-1000 ACS to Server.