Go to documentation repository
Page History
...
- Go to the settings panel of the Senstar object, which is created on the basis of the Computer object on the Hardware tab of the System Settings dialog box.
- In the IP (1) and Port (2) fields, enter the IP address and port number for working with the Intellect Axxon PSIM server on the computer to which the controllers are connected.
- Click the Read Cfg button (3).
As a result, the system configuration will be read and the objects tree will be created in ACFA PSIM: - In the Ping(sec) field (4), enter the period of time in seconds after which the connection between ACFA PSIM Server and the controllers will be checked. The default value is 10.
- To save the settings, click Apply (5).
...
Overview
Content Tools