Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To add the event parameters to ddi-DDI file, use the System configuration ddi.exe utility. Working with this utility is described in the Intellect Axxon PSIM software package. Administrator's Guide,  latest the latest version of which is available in in AxxonSoft documentation repository.

To add the event parameter, do the following:

  1. Shutdown the ACFA PSIM software package.
  2. Open Using the ddi.exe utility, open the .ddi file corresponding to the required integration module of the ACFA PSIM software using the ddi.exe utility.

    Info
    titleNote.

    Ddi DDI files are located in the <Intellect software Axxon PSIM installation directory>\Languages\en folder.


  3. Select the required object on the Names tab (1).
    Image Modified
  4. Go to the Events tab (1) and select the required event (2).
    Image Modified
  5. In the Parameter field, enter the parameter name displaying displayed in the Debug window (3) – see Event parameters in the Debug window section.
  6. In the Name field, enter the parameter name of parameter in in natural language form (4).
  7. From the Type drop-down list, select the parameter type:   EDIT (text) или COMBOBOX (set of values) (5). If the COMBOCOX COMBOBOX type is selected, specify available the possible parameter values in the Element and Value columns.
  8. Save the changes in the .ddi file.
  9. Start the ACFA PSIM software package.

The added parameter will be available to select for selection on the settings panel of the Axxon One data sender Data Bridge object when selecting the corresponding event in the Events column.

Image RemovedImage Added

Note
titleAttention!

Changed ddi-DDI files will be overwritten when updating the ACFA PSIM software. So create backup copies of the changed ddi-DDI files before updating the ACFA PSIM software and place them to into the <Intellect software installation Axxon PSIM installation directory>\Languages\En folder after updating.

  Adding  Adding the event parameters to the ddi-DDI file is completed.