Info
titleNote

You can use templates when you create a report.

To add a new template, click Report templatesNew template and fill in the Name and Description fields. The template will use the selected parameters of the current report.

Templates work the same way as templates in the scheduler and can be used interchangeably.

When you create a response using a template, click Report templates at the top of the page and select the required template from the list of saved templates (the required template is highlighted). As a result, the parameters of the current report are updated according to the selected template.

The Average queue length in time interval report provides the information on the average queue length. The data can be presented in the form of a chart or a table.

Info
titleNote

The Average queue length in time interval report is related to the Queue Length Detector module ( report is a part of the Queue length detection module, it is necessary to create and configure the corresponding object inAxxon PSIM DetectorPack PSIM (see Configuring the Queue length detection module).

To create the Average queue length in time interval report, do the following:

  1. Select the Average queue length in time interval report type (see Selecting a Select the type of reports by Queue Length detectors ). As a result the dialog box for specifying the report parameters will be displayed.
    Image Removedreports).
    Image Added
  2. From the Receiving data period drop-down list select the time period for which the report should be created (1).

    Info
    titleNote

    If the Custom or Custom 2 time period is selected, enter the start and end dates of the time period for which the report should be created in the from and to fields using the Calendar tool. Click the Image Removed button near the corresponding field to use the Calendar tool. It is also necessary to enter the time of start and end periods using the Image Removed button.

    In the Data averaging interval (min.)field (2), enter the calculation step of the time period in minutes queue length—the time interval between the congestion values of the monitored area in the report. The report displays the average values of the queue length over a time equal to the calculation step. The maximum and minimum values of this field depend on the selected Step type parameter.

    Info
    titleNote

    If the average value is null zero for all such intervals over a given specified period, that period will not be displayed in the report. In this case, it is recommended to change the calculation step.

  3. In the Detectors field (3), set the checkboxes for those Queue Length Detector objects which information should be displayed in the report.
  4. data averaging interval.

  5. Set the Chart checkbox (4), if it is necessary to display if you want to create the report in the form of a chart.
  6. From the Time zone

     drop

    drop-down list

    (5)

    , select the time zone for which the report

    is to

    must be created.

    Info
    titleNote.

    Time You can select time zones created in theAxxon PSIM software package which that have only one time period and havendon't got any inclusions are available to select. Selection of week days is not performed. Detailed have any nested time periods. You cannot select days of the week. For detailed information about creation and using of time zones is presented in the Creating and using time schedules section.

    To create a report, click Execute (6).

    , see Creating and using time schedules.

  7. From the Step type drop-down list, select the type of data averaging:
    1. empty—the data will be displayed as is, i.e., it won't be averaged. The Data averaging interval field isn't taken into account.
    2. seconds—the data will be averaged by seconds with a step in the range of 1-60 from the Data averaging interval field.
    3. minutes—the data will be averaged by minutes with a step in the range of 1-60 from the Data averaging interval field.
    4. hours—the data will be averaged by hours with a step in the range of 1-24 from the Data averaging interval field.
    5. days—the data will be averaged by days with a step in the range of 1-31 from the Data averaging interval field.
  8. From the Receiving data period drop-down list, select the time period for which the report must be created.

    1. If you select the Custom or Custom 2 time period, enter the start and end dates of the time period for which the report must be created in the from and to fields using the Calendar tool.
    2. If you select the Custom 2 time period, enter the time of the start and end period.
  9. In the Detectors area, set the checkboxes next to those Queue length detection objects whose information you want to include in the report. Click All to select all available detectors, click None to deselect. Click Show all to expand the detector structure. Click Hide all to hide the structure.
  10. By default, the list of detectors is sorted by name. To sort by number, select this option from the Sort by drop-down list.
  11. To create the report, click the Execute button.
    As a result, the report by the average queue length in time interval with the specified parameters
  12. will be
  13. is displayed.

Example of the report in the form of a table:.

Example of the report in the form of a chart:.

Info