For the precise tracking of the object under observation, you should must calibrate the telemetry device by matching at least six telemetry device positions with the frame points of each overview camera.
Note |
---|
|
- The recommended number of points that should must be set is 6-10. If you add more points, the algorithm will be configured more precisely. However, this may increase increases the chance that some of the points are set up incorrectly, which may cause causes the decrease of the operation quality.
- The points set in the calibration setting should must not be on the same line for both the overview and the PTZ camera. It is recommended to set the points for both cameras so that they evenly cover the entire frame.
- The calibration points should must be set on the same surface (floor, ground). It is not recommended to set the points on different surfaces (for example, when some points are on the ground, and other points are on a tree, etc.).
|
...
Note |
---|
|
The object under observation should must be inside the frame of the PTZ camera. |
...