Go to documentation repository
Page History
...
Manually add the Interop IP device to the configuration (see Searching, adding, configuring and removing IP devices).
- Enable the Embedded storage object.
Info title Note It is recommended to synchronize the time of the local Server with the time of the centralized Server.
- To receive sound from video cameras, configure the Microphone object.
Specify the address of the device in the following format (1): <IP-address of local Server>:<name of local Server in Axxon-domain>:<ID of camera on Server>.
Note title Attention! The Server name is case-sensitive.
If the Server name is Server1, then if you enter server1 or SERVER1 there will be no connection.
Specify a port of the local Server from which data is transmitted (2). If you use TCP protocol (see step 9), specify the RTSP port number (554 by default, see Configuring an the RTSP Serverserver). If you use rtspoverhttp or rtspoverhttps protocol, specify the Web server's port (80 by default, Configuring the Web-Server).
- Specify the user name and password (3). The user must have permissions to access the local server.
- If you want to display live video from the local server when it is available, select Yes in the corresponding field (4).
- Specify the maximum playback speed (5).
Select the data transfer protocol (6).
- Click the Apply button.
- Repeat the previous steps to add and configure all the necessary video cameras from all local Servers.
Configure automatic replication from the embedded storages of the added devices to the centralized server archive (see Configuring data replication).
Note title Attention! With a high network load, there may can be gaps in the centralized server archive.
...