Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to Hardware tab in the System settings dialog box.
  2. Create an IIDK interface object under on the basis of the Computer object. Set the IIDK Interface object identifier (1).
  3. Create a Server Of Control object based object on the basis of a Computer object. On the settings panel of this object, in the IIDK interface field (2), enter the identifier of the previously created IIDK Interface object.
  4. Create the required number of child Partition Of Control objects based child objects on the basis of the Server Of Control object. When you create these objects, specify the same ID (3) as in the ID field on the settings panel of the corresponding Partition Of Control object created under on the basis of the Agent Of Control object.

    Info
    titleNote

    It is not necessary to manually create the Partition Of Control objects based on the the basis of the Server Of Control object. They will be created automatically upon successful configuration of the communication between the Agent Of Control and the Server Of Control with the name and identifier specified on the Agent Of Control side (see Configuring communication between Agent Of Control and Server Of Control).


...