Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Queue length in time interval report provides the information on the queue length for the in time interval. The data can be presented in the form of a chart or a table.

Info
titleNote

The Queue length in time interval report is related to the Queue Length Detector module ( report is a part of the Queue length detection module, it is necessary to create and configure the corresponding object in Axxon PSIMDetectorPack PSIM (see Configuring the Queue length detection module).

To create the Queue length in time interval report, do the following:

  1. Select the Queue length in time interval report type (see Selecting a type of reports by Queue Length detectors). As a result, the dialog box for specifying the report parameters will be displayed.
  2. Set the Chart checkbox (1), if it is necessary to display the report in the form of a chart.
  3. From the Time zone drop-down list (2), select the time zone for which the report is to should be created.

    Info
    titleNote

    Time You can select time zones created in the Axxon PSIM software package which that have only one time period and havendon't got any inclusions are available to select. Selection of week days is not performed. Detailed have any nested time periods. You cannot select days of the week. For detailed information about creation and using of time zones is presented in the, see Creating and using time schedules section.


  4. From the Receiving data period drop-down list (3), select the time period for which the report should be created (3). If the Custom or Custom 2 time period is selected, enter the start and end dates of the time period for which the report should be created in the from and to fields using the Calendar tool. Click the  button near the corresponding field to use the Calendar tool. It is also necessary to enter the time of start and end periods using theIf the Custom 2 period is selected, enter additionally the start and end time of the period for which the report should be created using the  button.
  5. In the Detectors field (4), set the checkboxes for those Queue Length detectornext to those Queue length detection objects which information should be displayed in the report. Click All to select all found/available detectors. Clickavailable objects, click None to deselect. Click Show all to expand the detectors objects structure. Click Hide all to hide the detectors structure.
  6. To create a report, click click the Execute  button (5). As a result, the report by the queue length in time interval with the specified parameters will be displayed. Data averaging type depends on selecting time interval: 1 day by The data is displayed with averaging depending on the selected time interval. If you select more than 14 days period, one hour from 1 the data averaging is one day. If you select from one day to 14 days period, 1 minute by less a day period. , the data averaging is one hour. If you select less than one day, the data averaging is one minute.

Example of the report in the form of a table:

...