The table describes the parameters of the settings corresponding to the elements of the settings panel of the the Control panel object.
№
| Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Control panel object in the video surveillance system with |
distributed architecture |
Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Control panel objects in the video surveillance system with |
distributed architecture | |||
2 | The Name* | Enter the value in the field | Sets the name of the Control panel object in the video surveillance system with |
distributed architecture | Latin alphabet, Cyrillic |
, digits and service characters | Control panel | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 | |
3 | The Disable | Set the checkbox | Disables the Control panel object in the video surveillance system with |
distributed architecture | Boolean type | Clear | Set—the Control panel object is disabled and isn't used Clear—the Control panel object is enabled and is used |
4 | The Telemetry Controller | Select the value from the list | Sets the Telemetry Controller parent object of the system with |
distributed architecture to which the |
given Control panel object belongs |
Names of |
the Telemetry Controller objects registered in the system | Name of the Telemetry Controller parent object | Depends on the number of telemetry controllers in the video surveillance system with |
distributed architecture | ||||||
The Settings group | ||||||
5 | The Port | Select the value from the list | Sets the number of the computer serial (COM) port used to connect the |
control panel | List of available COM ports | COM1 | Depends on the number of COM ports on the server or Remote Administrator's workstation |
6 |
The Rate | Select the value from the list | Sets the data communication speed via the serial (COM) port | Kb/s | 9600 | From 300 to 256000 |
7 | The Parity | Select the value from the list | Sets the parity check mode for the data transmission over the serial (COM) port |
Names of the parity check modes | None | Even, Odd, None, Mark, Space | ||||
8 | The DTR checkbox | Set the checkbox | Disables the object | Boolean type | Set | Set—the power is supplied via the DTR port output Clear—the power isn't supplied via the DTR port output |
9 | The RTS | Set the checkbox | Disables the object | Boolean type | Set | Set—the power is supplied via the RTS port output Clear—the power isn't supplied |
via the RTS port output | |||
10 | The Priority | Select the value from the list | Sets the priority for controlling the PTZ devices via the |
control panel | Names of priorities used to control the PTZ devices | Low priority |
|
|
|
*Name of the element doesnisn't appear displayed in the settings panel of the given object.