Go to documentation repository
...
The table describes the setting parameters of the Charts interface object.
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
1 | The Identification number* | Automatically | Displays the identification number of the Charts |
object in the system |
Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the Charts objects in the system | ||
2 | The Name* | Enter the value in the field | Sets the name of the Charts object in the system | Latin alphabet, Cyrillic, |
digits, and service characters | Charts | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable |
| Set the checkbox | Disables the Charts object in the system | Boolean type | Clear | Set—the Charts object is disabled and isn't used Clear—the Charts object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object |
for the given Charts |
object | Names of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the system | |||
The Position group | ||||||
5 | The X field | Enter the value in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the Charts window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors |
The Y field | Enter the value in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the Charts window | % of the screen height | 44 | From 0 to M*100, where M is the number of the installed monitors |
6
The W field | Enter the value in the field | Sets the width of the Charts window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors |
The H field | Enter the value in the field | Sets the height of the Charts window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors |
The button
Opens the window for changing the position and size of the Charts window
8
Allow moving
The Allow moving | Set the checkbox | Allows moving the Charts |
window |
using the mouse | Boolean type | Clear | Set—allow moving the Charts |
window |
using the mouse Clear—disable moving the |
Charts window |
using the mouse |
The button | Click the button | Opens the window for setting the position and size of the Charts window | NA | NA | NA |
The Monitor drop-down list |
Select the value from the list |
Determines the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 | |||
The Objects |
table |
6 | The Number drop-down list | Select the value from the list | Sets the identifier of the Analog sensor object, the data from which must be displayed in the chart | Names of the Analog sensor objects | NA | Depends on the Analog sensor objects in the system |
The Name drop-down list |
Select the value from the list | Sets the name of the Analog sensor |
object, the data from which must be displayed in the chart | Names of the Analog sensor objects | NA | Depends on the Analog sensor objects in the system |
The Color drop-down list |
Select the value from the list | Sets the display color of the corresponding analog sensor |
in the chart in the Charts window | Color palette | Black | RGB color |
The Line width field | Enter the value in the field | Sets the width of the line in the chart | Sequence of numbers | 5 | >0 | |
Out of the group |
7 | The Number of pixels field | Enter the value in the field | Sets the number of pixels to be displayed in the chart | Integer numbers | 0 | >=0 |
*Name of the element isn't displayed in the settings panel of the given object.