New integrations and supported devices
...
New AxACFA integrations
FINE, ACS. Интегрировано устройство Integrated the FN-6535A . Реализована вычитка оборудования, получение состояний, управление дверьми.device. Implemented device reading, reception of statuses, and door control
New features and improvements
AxACFA modules
- Protege:в документацию добавлена информация о формате строки поля Address, неправильное заполнение которого вызывало проблемы с вычиткой конфигурации Updated the documentation and included the information about the format of the Address field, as incorrect filling of the field caused problems with configuration reading
RISCO Panel: в конфигурацию добавлены новые объекты RISCO Output и реализовано управление этими объектами. Added new RISCO Output objects to the configuration and implemented control of these objects
- APACS:Corrected localization APACS: правки локализации
- Modbus Slave: стабилизирована повторная вычитка конфигурации, работа транспорта, изменения значений регистров хранения и работа функции отслеживания этих изменений Stabilized the repeated reading of the configuration, transport operation, changes to values of the holding registers, and the operation of the change-tracking function
Integration modules
- BioSmart: исправлена динамическая запись уровней доступа Fixed the dynamic recording of access levels
- ZK Teco
- стабилизирована запись биометрических идентификаторов в устройства; исправлены ошибки при отправке команд на контроллер
- Stabilized the recording of biometric identifiers into devices.
- Fixed the errors that occurred when sending commands to the controller.
- Modbus Wrapper
- Fixed the logic of stopping the poll when polled registers are deleted.
- Fixed the problems with incorrectly determined error codes in the response from the Modbus device.
Fixed an infinite cycle of events when you tried to open a busy port.
Fixed the application of settings when you change the Modbus protocol and connection parameters.
Service modules
- Access Manager
- Added the ability to leave comments on access levels assigned to a user.
- Stabilized the operation of the Access Manager module and its debugging tools.
- Stabilized the re-accounting by protocol via the UpdateDB Utility. The re-accounting is started from the Worktime tab in the Access Manager interface window
- добавлены комментарии к уровням доступа, назначенных пользователю; стабилизирована работа самого модуля Бюро пропусков и его отладочных инструментов
- .
Bug fixes
Fixed some errors in the ACS, FSA, PID modules. Improved the stability and performance of the system.
...