The settings panel of the Monitor interface object is shown in the figures.

The Basic settings tab

 

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

The Identification number*
field

Automatically

Displays the identification number of the Monitor object in the system

Digits, letters, periods, hyphen, dash, and underscore

NA

A line containing numbers, letters, periods, hyphen, dash, and underscore

Depends on the number of the Monitor objects in the system

2

The Name*
field

Enter the value in the field

Sets the name of the Monitor object in the system

Latin alpabet, Cyrillic,

numbers

digits and service characters

Monitor

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

The Disable
checkbox

Set the checkbox

Disables the Monitor object in the system

Boolean type

Clear

Setthe Monitor object is disabled and isn't used

Clearthe Monitor object is enabled and used

4

The Display
drop-down list

Select the value from the list

Sets the Display parent object for the given Monitor object

Names of the Display objects registered in the system

Name of the Display parent object

Depends on the number of the Display objects in the system

The Coordinates group

5

The X field

Enter the value in the field

Sets the X coordinate in the horizontal axis for the upper left corner of the Monitor window

% of the screen width

60

From 0 to M*100, where M is the number of the installed computer monitors

6

The Y field

Enter the value in the field

Sets the Y coordinate in the vertical axis for the upper left corner of the Monitor window

% of the screen height

50

From 0 to M*100, where M is the number of the installed computer monitors

7

The W field

Enter the value in the field

Sets the width of the Monitor window

% of the screen width

40

From 20 to 900 if control panel is enabled. Otherwise, from 0 to 900.

You can disable this restriction using the UnlimitMonitorSize registry key (see Registry keys reference guide)

8

The H field

Enter the value in the field

Sets the height of the Monitor

 object if

window if the control panel is disabled

% of the screen width

40

From 0 to 900.

You can disable this restriction using the UnlimitMonitorSize registry key (see Registry keys reference guide)

9

The Monitor
drop-down list

Select the value from the list

Sets the number of the physical monitor, the coordinates for which are set. The monitors are numbered in the order of their physical location from left to right, from top to bottom. The number 1 corresponds to the upper left monitor regardless of which monitor is the main one or the first one in OS.

In the figure below, the monitor numbers in OS are given in gray while the numbers in Axxon PSIM are red.

Image Modified

Note
titleAttention!

We recommend setting the same resolution for all monitors in the system. Different resolution is only allowed if all monitors are aligned along any border (for example, the upper border)

Sequence of numbers

1

From 1 to 16

10

The Allow moving checkbox

Set the checkbox

Allows moving the the Monitor window object using the mouse, if the control panel is enabled

Boolean type

Clear

Set—allow moving the Monitor window object using the mouse

Clear—forbid moving the Monitor window object using the mouse

11

The Image Modified button

Click the buttonOpens the window for setting the position and size of the Monitor windowNANANA
The Quad splitter group
12The horizontal
field
Enter the value in the field

Sets the number of the surveillance windows that must be displayed horizontally on the monitor. If the value isn't specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

Sequence of numbers
Blank fied
NA

From 1 to 64

.

Blank fied—the default grid of the surveillance windows depending on the selected layout is displayed


13The vertical
field
Enter the value in the field

Sets the number of the surveillance windows that must be displayed vertically on the monitor. If the value isn't specified (the field is blank), then the default grid of the surveillance windows depending on the selected layout is displayed

Sequence of numbers
Blank fied
NA

From 1 to 64

.

Blank fied—the default grid of the surveillance windows depending on the selected layout is displayed


The Basic settings tab

14

The Display
drop-down list

Select the value from the list

Sets the mode for processing the video signals from

the

cameras by the graphics card

Names of the display modes

Opengl

  • Opengl is selected by default. This mode uses the most advanced Windows graphics libraries for rendering 2D and 3D graphics;
  • Direct3D

    • Direct3D is the recommended mode that uses the most advanced Windows graphics libraries.
    Use this mode when you need to display the video from the fisheye cameras or the signal decoded using Intel QuickSync technology;
    • DirectDraw is used if the graphics card doesn't support Direct3D;
    • Softwarevideo signals aren't processed by the graphics card. It is used if Axxon PSIM is installed on a virtual platform

    15


    The switch of displaying the camera window*

     

     

    Active camera

    Sets in the position

    Sets the display mode for an active camera window only

    Boolean type


    Clear

    Setthe Active camera mode is enabled and used

    Clear—the Active camera mode is disabled and isn't used

    Alarm cameras

    Sets the display mode for alarm cameras windows

    Clear

    Setthe Alarm cameras mode is enabled and used

    Clear—the Alarm cameras mode is disabled and isn't used

    List

    Sets the display mode of the camera windows according to the selected layout

    Set

    Set—the List mode is enabled and used

    Clearthe List mode is disabled and isn't used

    16

    The Control panel checkbox

    Set the checkbox

    Enables the display of the toolbar on the monitor in the List mode

    Boolean type

    Clear

    Setthe control panel is enabled and used

    Clearthe control panel is disabled and isn't used

    17

    The Use button attached to camera
    checkbox

    Set the checkbox

    Enables the display of the Button objects attached to cameras in the surveillance windows

    Boolean type

    Clear

    Set—buttons are displayed in the surveillance windows

    Clear—buttons aren't displayed

    18

    The Max field

    Enter the value in the field

    Sets the maximum number of the cameras windows that can be simultaneously displayed on the monitor in the Alarm cameras and List modes. If the number of alarm cameras is greater than the maximum number, the monitor will display the number of cameras no more than specified in the Max field

    Sequence of numbers

    NA

    >0

    Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras

    19

    The Min field

    Enter the value intthe field

    Sets the minimum number of video cameras windows that can be displayed on the monitor in the Alarm camers mode. If the number of the alarm cameras is less than the minimum number, the monitor will display fewer cameras than specified in the Min field. At the same time, the monitor fold will remain consistent with the Min field

    An integer from zero and greater (for example, 0, 2, 50)

    NA

    >=0

    Depends on the number of the cameras registered in the system. There are no restrictions on the number of cameras.

    0—when there are no alarms, the camera windows aren't displayed in the monitor window

    20

    The Keep camera ratio
    checkbox

    Set the checkbox

    Sets the ratio of the width and height of the video image in the surveillance windows on the video surveillance monitor

    Boolean type

    Clear

    Setthe ratio of the width and height of the video image corresponds to the ratio of the camera

    Clearvideo image occupies the entire area of the surveillance window, while the ratio maynot be saved

    21

    The Show captions
    checkbox

    Set the checkbox

    Shows the captions for the cameras of the

     m

    Monitor window.

    In large distributed systems, we recommend disabling captions on those monitors where you don't need to show captions.

    This checkbox also affects the display of frames around detected objects or abandoned objects (see Smart video detection tools operation) when viewing the archive

    Boolean type

    Set

    Setthe captions 

    Captions 

    submenu is available in the context menu of the monitor window, captions are displayed. The frames generated by the VMDA smart video detectors are displayed

    Clearthe

     Captions submenu

    captions submenu is unavailable in the context menu of the

     m

    Monitor window, captions aren't displayed. The frames generated by the VMDA smart video detectors aren't displayed

    22

    The Smoothing
    checkbox

    Set the checkbox

    It is used when you need to display a video with greater resolution on which the ladder effect appears when displaying in the small window.

    Note. When this feature is enabled, the CPU load of the computer where the display is performed increases. We recommend displaying video from analog cameras or low-resolution video only

    Boolean type

    Clear

    Setsmoothing is applied

    Clearsmoothing isn't applied

    23

    The PTZ control
    drop-down list

    Select the value from the list

    Sets the priority to control the PTZ devices using the Monitor object

    Names of the PTZ devices control priorities

    Low priority

    • Forbidden—the option of the PTZ control using the Monitor object is disabled;
    • Low prioritylow priority of control;
    • Normal priority—medium priority of control;
    • High priorityhigh priority of control

    24

    The Slideshow__ s
    field

    Enter the value in the field

    Sets the period of the automatic slideshow of the camera windows when the control panel is enabled

    Time in seconds (s)

    Blank field

    Blank field or 0the camera windows are scrolled every 3 seconds

    An integer from 1 to 600the camera windows are scrolled at the specified interval

    25

    The Audio player
    drop-down list

    Select the value from the list

    Sets the Audio player object used to playback the audio signals and export video recordings with audio from the monitor interface

    Names of the Audio player objects registered in the system

    NA

    Depends on the number of the audio players registered in the system

    26

    The Select camera with grouping and search
    checkbox

    Set the checkbox

    Enables a dialog window for switching a camera in the surveillance window in which cameras are grouped by computers, and you can search them by their name (see Selecting camera to display in Surveillance window)

    Boolean type

    Set

    Set—to switch to another camera, a special dialog window in which cameras are grouped and has a search line opens

    Clear—camera is selected in the function menu of the surveillance window without opening a special dialog window

    27Group of checkboxes used to display the elements of the Surveillance windows Set the checkboxesAllows enabling and disabling the display of various elements of the surveillance window such as number, name, time, menu, camera frame and additional info on the camera, as well as the name of the video surveillance monitorBoolean typeAll checkboxes are set except of the Additional info checkbox

    Setthe corresponding element is displayed in the surveillance windows of all cameras added to the video surveillance monitor

    Clearthe corresponding element isn't displayed in the surveillance windows on the video surveillance monitor

    *Name of the element isn't displayed in the settings panel of the given object

    The List of cameras tab

     

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    The Cameras* table

    1

    The Number
    drop-down list

    Select the value from the list

    Sets the number of the camera to display on the monitor

    Sequence of numbers

    NA

    Depends on the number of the cameras registered in the system

    The Camera
    drop-down list

    Select the value from the list

    Sets the name of the camera to display on the monitor

    Names of the cameras registered in the system

    NA

    Depends on the number of the cameras registered in the system

    The Video stream
    drop-down list

    Select the value from the list

    Sets the number of the video stream displayed from the camera when connected directly. If connected via the server, this setting doesn't affect anything

    Numbers of the video streams

    Default

    1, 2, 3, 4video streams numbers

    Defaultdefault video stream

    The Connection
    drop-down list
     

    Select the value from the list

    Sets the way of receiving video image from the camera

    Ways of receiving video from camera

    Through server

    Directthe video stream is received directly from camera

    Through serverthe video stream is received from the server, to which the camera is connected

    The fps
    drop-down list

    Select the value from the list

    Sets the fps for transmitting the video signal to the client monitor

    Sequence of numbers

    Blank field

    1, 2, 3, 4, 6, 8, 12, 16, 20, 25, 30

    Blank field—fps value from the camera settings

    The Hardware decoding
    drop-down list

    Select the value from the list

    Sets the hardware decoder of the video signal. When you select a hardware decoder, it increases the load on the corresponding CPU

    List of available decoders

    Blank field 

    • Blank field (default CPU decoder),
    • Nvidia decoder,
    • Intel Quick Sync

    The Compression
    drop-down list

    Select the value from the list

    Sets the compression level for transmitting the video signal to the client monitor. The given value leads to extra consumption of server resources

    Sequence of numbers

    NA

    In the order of increasing the compression level from 0 to 5.

    0—no compression

    5maximum compression

    The Compressor
    drop-down list

    Select the value from the list

    Sets the algorithm for the video stream compression which is used for the video signal recompression when displaying on the monitor. If you set the compressor, you must set the value in the Compression list

    List of available algorithms

    NA

    • MJPEG,
    • Motion Wavelet 3.5,
    • MPEG4

    The Gate
    drop-down list

    Select the value from the list

    Sets the Videogate object via which the live and archive video from the selected camera must be transmitted to the monitor

    Names of the Videogate objects registered in the system

    NA

    Depends on the number of the Videogate objects registered in the system

    The Backup archive
    drop-down list

    Select the value from the list

    Sets the Backup archive object from which the video archive from the selected camera must be transmitted to the monitor

    Names of the Backup archive objects registered in the system

    NA

    Depends on the number of the Backup archive objects registered in the system

    The Edge storage
    drop-down list

    Select the value from the list

    Sets the Edge storage object from which the video archive must be transmitted to the monitor via the selected camera

    Names of the Edge storage objects registered in the system

    NA

    Depends on the number of the Edge storage objects registered in the system

    The Gateway for Backup archive
    drop-down list

    Select the value from the list

    Sets the Videogate object via which the video archive from the Backup archive object must be transmitted to the monitor

    Names of the Videogate objects registered in the system

    NA

    Depends on the number of the Videogate objects registered in the system

    The VMDA metadata storage
    drop-down list
    Select the value from the listSets the VMDA metadata storage object used for the forensic search in the archive of the corresponding cameraNames of the VMDA metadata storage objects registered in the systemNADepends on the number of the VMDA metadata storage objects registered in the system
    The Type of display
    drop-down list
    Select the value from the listSets the type of conversion performed in the surveillance window on the video surveillance monitorSupported conversion typesPTZ

    PTZvirtual telemetry

    Panoramapanoramic view of the image

    The Macro1
    drop-down list
    Select the value from the listSets the first macro to be displayed in the function menu of the camera in the surveillance windowNames of the Macro objects registered in the systemNADepends on the number of the Macro objects registered in the system
    The Macro2
    drop-down list
    Select the value from the listSets the second macro to be displayed in the function menu of the camera in the surveillance windowNames of the Macro objects registered in the systemNADepends on the number of the Macro objects registered in the system
    The Guid
    field
    AutomaticallyDisplays the unique identifier of the camera in the systemSequence of numbers, Latin alphabet, digits and service charactersNAA line containing a sequence of any characters (letters, digits, service characters) enclosed in {curly brackets}

    2

    The Range
    button

    Click the button

    Opens the Add/ Edit cameras window and appears the access to complex selection and editing of cameras parameters for displaying on the monitor

    NA

    NA

    NA

    3

    The All button

    Click the button

    Selects all cameras registered in the system for displaying on the monitor

    NA

    NA

    NA

    4

    The Automatic selection of streams for display
    checkbox

    Set the checkbox

    Enables the function of automatic selection of video stream for displaying on the monitor. Affects cameras for which the Default video stream is selectedsee item 28

    Boolean type

    Clear

    Setvideo stream for display is selected depending on the size of the video image on the monitor and the required frame frequency

    Clearvideo stream is selected depending on the Video stream and Connection settings (item 28) and on the settings of the server and camera from which the stream is required

    The PTZ tab

     

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    The Mouse group

    1

    The Behavior list

    NA

    The list of possible actions with a mouse

    NA

    NA

    NA

    2

    The Action
    drop-down lists

    Select the value from the list

    Sets the reaction performed when executing the corresponding action with a mouse

    Reaction list of the PTZ device object

    (Default)

    Reaction list of the PTZ device object

    3

    The Param. fields

    Enter the value in the field

    Sets the value of the reaction parameter if it’s required

    Depends on the selected action

    NA

    Depends on the selected reaction. For the reactions connected with the presets, it is a preset number. For other reactions, it is speed if the selected reaction allows specifying speed as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the Camera seleected on the Monitor, is used

    The Joystick group

    4

    The Butt.
    list

    NA

    List of joystick buttons

    NA

    NA

    NA

    5

    The Action
    drop-down lists


    Select the value from the list

    Sets the reaction which must performed when you click the joystick button

    List of reaction of the PTZ device object

    (Default)

    List of reaction of the PTZ device object


    6

    The Param. fields

    Enter the value in the field

    Sets the value of the reaction parameter if it is required

    Depends on the selected action

    NA

    Depends on the selected reaction. For the reactions connected with the presets, it is the preset number. For other reactions, it is speed; if the selected reaction allows specifying speed as a parameter. If the parameter isn't specified, the speed value from the settings of the PTZ device object that is connected with the camera and selected on the monitor, is used

    The Interface tab

     

    Parameter

    Method for setting the parameter value

    Parameter description

    Representation

    Default value

    Value range

    1

    The Alarm
    drop-down window

    Select the color

    Sets the frame color of the surveillance window in the alarm state

    RGB colorsRedRGB color palette
    The Armed
    drop-down window
    Select the color

    Sets the frame color of the surveillance window when the camera is armed

    RGB colorsOrangeRGB color palette
    The Disarmed
    drop-down window
    Select the colorSets the frame color of the surveillance window when the camera is disarmedRGB colorsGreenRGB color palette
    The No frame 
    drop-down window
    Select the colorSets the frame color of the surveillance window when there is no frame in itRGB colorsBlackRGB color palette
    The No signal
    drop-down window
    Select the colorSets the frame color of the surveillance window when there is no signal from cameraRGB colorsGreyRGB color palette
    The Screen cache
    drop-down window
    Select the colorSets the surveillance window background color that is displayed when video doesn't cover completely the surveillance window, for example, when the camera proportions are maintainedRGB colorsPurpleRGB color palette
    The Tracker frame color
    drop-down window
    Select the colorSets the frame color to highlight the tracking objects on the videoRGB colorsWhiteRGB color palette
    2The Default
    button
    Click the button

    Sets the default frame colors of the surveillance window

    NANANA
    3The Hide capture frames
    checkbox
    Set the checkboxHides the frames displayed by the Face detector module when a person’s face is detected on the video imageBoolean typeClear

    Setthe face detector frames aren't displayed

    Clearthe face detector frames are displayed

    4The Over all windows
    checkbox
    Set the checkboxEnables the display of the video surveillance monitor over all windowsBoolean typeClear

    Setthe video surveillance monitor is displayed over all windows

    Clearthe video surveillance monitor is displayed in the default mode